0.16-0.24 dL/g, 0.5 % (w/v) in chloroform(25 °C, Ubbelohde) (size 0c glass capillary viscometer)
transition temp
Tg 42-46 °C
shipped in
wet ice
storage temp.
2-8°C
Application
Resomer® RG 502 puede utilizarse para formular un sistema de administración de nanomedicamentos basado en PLGA para el antiinflamatorio, éter de 6-bromoindirubina-3′-glicerol-oxima (6BIGOE).
También puedeutilizarse para preparar formulaciones de liberación controlada para la administración de HCl de naloxona.
Features and Benefits
Biocompatible
Biodegradable
Puede procesarse en casi cualquier forma y tamaño
Propiedades mecánicas ajustables
Legal Information
Producto de Evonik
RESOMER is a registered trademark of Evonik Rohm GmbH
Journal of the American College of Surgeons, 218(1), 102-107 (2013-11-12)
Chronic pain after inguinal hernia repair occurs in 16% to 62% of patients. The underlying mechanism probably involves sensory nerve damage and abnormal healing that might be influenced by the materials chosen for the procedure. We hypothesize that nonabsorbable sutures
To compare wrapped and polymer-coated hydroxyapatite implants in children undergoing primary enucleation with no adjuvant therapies. Retrospective, interventional cohort study. All children undergoing primary enucleation without adjuvant therapies between 1999 and 2009 at a tertiary pediatric cancer hospital. Review and
International journal of pharmaceutics, 440(2), 135-140 (2012-10-20)
Melatonin, a neurohormone secreted by the pineal gland, is able to modulate intraocular pressure (IOP). The aim of this study was to generate nanoparticle (NPs) sustained release formulations that allow to extend the pre-corneal residence time of melatonin, thus prolonging
Proceedings of the National Academy of Sciences of the United States of America, 106(14), 5497-5502 (2009-03-27)
Materials that combine facile synthesis, simple tuning of degradation rate, processability, and biocompatibility are in high demand for use in biomedical applications. We report on acetalated dextran, a biocompatible material that can be formed into microparticles with degradation rates that
International journal of surgery (London, England), 11(1), 81-84 (2012-12-19)
Chronic pain may be a major long-term problem related to mesh material and operative trauma in inguinal hernioplasty. Lichtenstein hernioplasty was performed under local anaesthesia in 312 patients by the same surgeon and technique between 2003 and 2005. The patients
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.