Skip to Content
Merck
All Photos(3)

Key Documents

186562

Sigma-Aldrich

Tetrahydrofuran

Tetrahydrofuran
1 of 2 reviewers received a sample product or took part in a promotion

≥99.9%, anhydrous, contains 250 ppm BHT as inhibitor

Synonym(s):

THF, Butylene oxide, Oxolane, Tetramethylene oxide

Sign Into View Organizational & Contract Pricing


About This Item

Empirical Formula (Hill Notation):
C4H8O
CAS Number:
Molecular Weight:
72.11
Beilstein:
102391
EC Number:
MDL number:
UNSPSC Code:
12191501
PubChem Substance ID:
NACRES:
NA.21
grade:
anhydrous
Assay:
≥99.9%
bp:
65-67 °C (lit.)
vapor pressure:
114 mmHg ( 15 °C)
143 mmHg ( 20 °C)
To inquire about this product 186562, please contact your local Merck office or dealer. Contact Technical Service

Product Name

Tetrahydrofuran, anhydrous, contains 250 ppm BHT as inhibitor, ≥99.9%

grade

anhydrous

Quality Level

vapor density

2.5 (vs air)

vapor pressure

114 mmHg ( 15 °C)
143 mmHg ( 20 °C)

Assay

≥99.9%

form

liquid

autoignition temp.

610 °F

contains

250 ppm BHT as inhibitor

expl. lim.

1.8-11.8 %

impurities

≤0.005% peroxides (as H2O2)
<0.002% water (All units except 100 mL)
<0.005% water (100 mL pkg)

refractive index

n20/D 1.407 (lit.)

pH

~7

bp

65-67 °C (lit.)

mp

−108 °C (lit.)

solubility

H2O: soluble

density

0.889 g/mL at 25 °C (lit.)

SMILES string

C1CCOC1

InChI

1S/C4H8O/c1-2-4-5-3-1/h1-4H2

InChI key

WYURNTSHIVDZCO-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

General description

Tetrahydrofuran (THF) is a saturated cyclic ether mainly used as an organic solvent. On long term storage it forms organic peroxides. This process can be suppressed by adding butylated hydroxytoluene (BHT) as a stabilizer. BHT removes the free radicals required for the peroxide formation. It constitutes the key fragment of various natural products (polyether antibiotics).[1] THF forms double hydrate with hydrogen sulfide, crystal structure of this double hydrate has been investigated by three-dimensional single-crystal studies.[2]

Application

Dry tetrahydrofuran (THF) has been used in the synthesis of dichloro{bis[1,1′,1′′-(phosphinetriyl)tripiperidine]}palladium [(P(NC5H10)3)2Pd(Cl)2], which is widely used in the Heck reaction as a catalyst. It has been employed in the reaction medium of the Heck cross-coupling reaction of various aryl bromides and olefins.[3]

Other Notes

Greener alternatives are available for many THF applications, 2-Methyltetrahydrofuran (414247) and Cyclopentyl methyl ether (675970)

Signal Word

Danger

Hazard Classifications

Acute Tox. 4 Oral - Carc. 2 - Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3

Target Organs

Central nervous system, Respiratory system

Supplementary Hazards

Storage Class Code

3 - Flammable liquids

WGK

WGK 1

Flash Point(F)

-6.2 °F - closed cup

Flash Point(C)

-21.2 °C - closed cup

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Mizoroki-Heck Cross-coupling Reactions Catalyzed by Dichloro {bis [1, 1', 1''-(phosphinetriyl) tripiperidine]} palladium Under Mild Reaction Conditions.
Oberholzer M and Frech CM
Journal of Visualized Experiments, 85, e51444-e51444 (2014)
Maria Laura Pati et al.
Pharmacological research, 117, 67-74 (2016-12-23)
A controversial relationship between sigma-2 and progesterone receptor membrane component 1 (PGRMC1) proteins, both representing promising targets for the therapy and diagnosis of tumors, exists since 2011, when the sigma-2 receptor was reported to be identical to PGRMC1. Because a
Francesco Berardi et al.
Journal of medicinal chemistry, 52(23), 7817-7828 (2009-10-22)
sigma(2)-Agonist 1-cyclohexyl-4-[3-(5-methoxy-1,2,3,4-tetrahydronaphthalen-1-yl)propyl]piperazine (7, PB 28), which proved to revert doxorubicin resistance in breast cancer cells, was taken as a template to prepare new analogs. One of the two basic N-atoms was alternatively replaced by a methine or converted into an
Mauro Niso et al.
Chembiochem : a European journal of chemical biology, 16(7), 1078-1083 (2015-03-11)
Although sigma-2 (σ2 ) receptors are still enigmatic proteins, they are promising targets for tumor treatment and diagnosis. With the aim of clarifying their role in oncology, we developed a σ2 -selective fluorescent tracer (compound 5) as a specific tool
Maria Laura Pati et al.
BMC cancer, 17(1), 51-51 (2017-01-15)
Despite considerable efforts by scientific research, pancreatic cancer is the fourth leading cause of cancer related mortalities. Sigma-2 receptors, which are overexpressed in several tumors, represent promising targets for triggering selective pancreatic cancer cells death. We selected five differently structured

Articles

A description of stabilizer systems for solvents including esters, ethyl ester, tetrahydrofuran, chlorinated solvents, chloroform and dichloromethane.

Substances are said to be miscible in one another if they dissolve to form a uniform solution. Bookmark or download our miscibility table for common lab solvents.

Solid-state lithium fast-ion conductors are crucial for safer, high-energy-density all-solid-state batteries, addressing conventional battery limitations.

Questions

1–10 of 10 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Is it necessary to use a coupling for the Pure pac 2?

    1 answer
    1. Yes, the Pure pac 2 requires a coupling.

      Helpful?

  4. Why do peroxides form in certain solvents and how do I test for it?

    1 answer
    1. A significant number of laboratory solvents can undergo autoxidation under normal storage conditions to form unstable and potentially dangerous peroxide by-products. Molecular structure is the primary factor relating to a material’s potential for hazardous peroxide formation.  It is important to understand the stability of materials in use and if unclear, consult Sigma-Aldrich Technical Support, [email protected]

      Helpful?

  5. What apparatus do you recommend for HPLC solvent filtration?

    1 answer
    1. The Sigma-Aldrich Vacuum Filtration Assembly gives you all the components you need including: funnel top, fritted glass funnel support, filtration flask, aluminum clamp, and silicone stopper.  The Acrodisc Syringe Filters offer high quality filtration for analytical samples, certified for HPLC to ensure low extractable and available in a broad range of membranes to meet sample compatibility requirements.

      Helpful?

  6. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  7. Who do I contact about larger solvent volume needs?

    1 answer
    1. Email us at [email protected] or visit Sigma-Aldrich Fine Chemicals for development and manufacturing-scale inquiries: [email protected]

      Helpful?

  8. What are the options for drying solvents?

    1 answer
    1. Sigma-Aldrich offers a full range of high-purity solvents with extremely low water levels specifically manufactured for moisture sensitive Organic and Biotech applications.  Sigma-Aldrich also carries various drying agents such as molecular sieves, which are typically compatible with organic solvents.

      Helpful?

  9. What are some of the preservatives used in the most common ethers and chlorinated solvents and why are they added?

    1 answer
    1. Certain solvents will degrade over time requiring special handling and storage considerations. In addition, the products of certain degradation processes pose a potential safety risk if present at sufficiently high levels. For these types of materials, small amounts of stabilizing chemicals are added to slow down or stop material degradation.

      Helpful?

  10. Can you recommend a Solvent Extractor for organics from aqueous solution?

    1 answer
    1. Solvent extractors are often used for the quantitative extraction of organics from aqueous solutions and separations in immunoassays. The MIXXOR system has been applied successfully in many laboratory solvent extraction operations and is ideal for the rapid screening of alternative solvents for specific extraction problems.

      Helpful?

Reviews

1 of 2 reviewers received a sample product or took part in a promotion

Active Filters

  1. Cambridge
    • Reviews 7
    • Votes 14
    5 out of 5 stars.

    THF

    Very good quality THF. Reactions done with this solvent went well.

    Helpful?

  2. 1 Ratings-Only Review

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service