  • Development of a Fully-automated On-line Oxidation Column-switching HPLC System for the Determination of Endogenous Melatonin in Human Clinical Samples.

Development of a Fully-automated On-line Oxidation Column-switching HPLC System for the Determination of Endogenous Melatonin in Human Clinical Samples.

Analytical sciences : the international journal of the Japan Society for Analytical Chemistry (2015-11-13)
Tsubasa Oyama, Rie Nagai, Mayumi Fujimoto, Ryoko Konishi, Masashi Mita, Keiko Uezono, Kiyoshi Zaitsu, Kenji Hamase
ABSTRACT

A fully-automated on-line oxidation column-switching HPLC system has been developed for the determination of endogenous melatonin in human plasma and saliva. This HPLC system consists of four processes. In the first step, melatonin is fractionated using a reversed-phase C4 column (Proteonavi, 75 mm × 1.0 mm i.d.). In the second step, the obtained melatonin fraction is on-line collected, and oxidized to a highly-fluorescent compound, N-[(6-methoxy-4-oxo-1,4-dihydroquinolin-3-yl)methyl]acetamide (6-MOQMA), by mixing with hydrogen peroxide under alkaline conditions. In the third step, the produced 6-MOQMA is concentrated, and the oxidation reagents are removed using an alkaline resistive reversed-phase column, Asahipak ODP (35 mm × 1.0 mm i.d.). In the final fourth step, the 6-MOQMA is determined by a microbore-ODS column packed with ultrafine particles (CAPCELL PAK C18 IF, 250 mm × 1.0 mm i.d.). The limit of detection of melatonin using this system is about 200 amol/injection, and the determination of endogenous melatonin in a small volume of human physiological fluids, such as 100 μL of plasma and 300 μL of saliva, was successfully accomplished.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Sigma-Aldrich
Acetonitrile solution, contains 10.0% acetone, 0.05% formic acid, 40.0% 2-propanol
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Tetrahydrofuran, anhydrous, contains 250 ppm BHT as inhibitor, ≥99.9%
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Sodium carbonate, anhydrous, powder, 99.999% trace metals basis
Sigma-Aldrich
Methanol, NMR reference standard
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Sodium carbonate, BioXtra, ≥99.0%
Sigma-Aldrich
Hydrogen peroxide solution, 30 % (w/w) in H2O, contains stabilizer
Sigma-Aldrich
Methanol, low water for titration
Sigma-Aldrich
Sodium carbonate, BioUltra, anhydrous, ≥99.5% (calc. on dry substance, T)
Sigma-Aldrich
Hydrogen peroxide solution, 34.5-36.5%
Sigma-Aldrich
Hydrogen peroxide solution, semiconductor grade VLSI PURANAL (Honeywell 17606), ≥30%
Sigma-Aldrich
Hydrogen peroxide solution, semiconductor grade MOS PURANAL (Honeywell 17937), ≥30%
Sigma-Aldrich
Tetrahydrofuran, anhydrous, ≥99.9%, inhibitor-free
Sigma-Aldrich
Tetrahydrofuran, suitable for HPLC, ≥99.9%, inhibitor-free
Sigma-Aldrich
Methanol, anhydrous, ≥99.5%
Sigma-Aldrich
Methanol, AR, ≥99.5%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, LR, ≥99%
Sigma-Aldrich
Sodium carbonate, LR, ≥99%
Sigma-Aldrich
Hydrogen peroxide solution, AR, contains sodium pyrophosphate as stabilizer, ≥30 % (w/v)
Sigma-Aldrich
Hydrogen peroxide solution, LR, contains sodium pyrophosphate as stabilizer, ≥30 % (w/v)
Sigma-Aldrich
Tetrahydrofuran, anhydrous, contains 250 ppm BHT as stabilizer, ≥99.5%
Sigma-Aldrich
Tetrahydrofuran, LR, contains 250 ppm BHT as stabilizer, ≥99%
Sigma-Aldrich
Hydrogen peroxide solution, LR, contains sodium pyrophosphate as stabilizer, ≥50 % (w/v)
Sigma-Aldrich
Tetrahydrofuran, AR, contains 250 ppm BHT as stabilizer, 99.5%