推荐产品
等級
analytical standard
品質等級
化驗
≥97.0% (HPLC)
光學活性
[α]1.15/D -0.5±0.5° in chloroform
儲存期限
limited shelf life, expiry date on the label
藥物控制
USDEA Schedule IIIN; regulated under CDSA - not available from Sigma-Aldrich Canada
技術
HPLC: suitable
gas chromatography (GC): suitable
應用
clinical testing
格式
neat
官能基
ketone
儲存溫度
2-8°C
SMILES 字串
C[C@]1(O)CC[C@H]2[C@@H]3CCC4=CC(=O)C=C[C@]4(C)[C@H]3CC[C@]12C
InChI
1S/C20H28O2/c1-18-9-6-14(21)12-13(18)4-5-15-16(18)7-10-19(2)17(15)8-11-20(19,3)22/h6,9,12,15-17,22H,4-5,7-8,10-11H2,1-3H3/t15-,16+,17+,18+,19+,20+/m1/s1
InChI 密鑰
XWALNWXLMVGSFR-HLXURNFRSA-N
基因資訊
human ... AR(367)
正在寻找类似产品? 访问 产品对比指南
一般說明
17β-hydroxy-17-methylandrosta-1,4-dien-3-one is an androgenic anabolic steroid.
應用
17β-hydroxy-17-methylandrosta-1,4-dien-3-one may be used as a reference standard in the determination of 17β-hydroxy-17-methylandrosta-1,4-dien-3-one in urine samples, using by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
包裝
Bottomless glass bottle. Contents are inside inserted fused cone.
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
其他客户在看
Comparative study of matrices for their use in the rapid screening of anabolic steroids by matrix?assisted laser desorption/ionisation time?of?flight mass spectrometry
Rapid Communications in Mass Spectrometry, 23, 1783-1791 (2009)
Archives of toxicology, 86(1), 109-119 (2011-08-06)
There is increasing evidence that the biological activity of myostatin (MSTN), a negative regulator of muscle growth, is affected by training but also anabolic steroids. In this study, we analyzed the effects of the frequently abused anabolic steroid methandienone (Md)
Drug testing and analysis, 1(11-12), 554-567 (2010-04-01)
Anabolic steroids are among the most frequently detected compounds in doping analysis. They are extensively metabolized and therefore an in-depth knowledge about steroid metabolism is needed. In this study, a liquid chromatography tandem mass spectometry (LC-MS/MS) method based on a
Biological chemistry, 391(1), 119-127 (2009-11-19)
Anabolic-androgenic steroids are some of the most frequently misused drugs in human sports. Recently, a previously unknown urinary metabolite of metandienone, 17beta-hydroxymethyl-17 alpha-methyl-18-norandrosta-1,4,13-trien-3-one (20OH-NorMD), was discovered via LC-MS/MS and GC-MS. This metabolite was reported to be detected in urine samples
Rapid communications in mass spectrometry : RCM, 24(7), 958-964 (2010-03-09)
We examined the feasibility of capillary liquid chromatography/microchip atmospheric pressure photoionization tandem mass spectrometry (capLC/microAPPI-MS/MS) for the analysis of anabolic steroids in human urine. The urine samples were pretreated by enzymatic hydrolysis (with beta-glucuronidase from Helix pomatia), and the compounds
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门