推荐产品
品質等級
物種活性
human
製造商/商標名
Milliplex®
assay range
accuracy: 100%
(IL-6)
accuracy: 102%
(TNFα)
accuracy: 103%
(MCP-1)
accuracy: 83%
(PAI-1 (total))
accuracy: 99%
(HGF)
sensitivity: 0.2 pg/mL
(MinDC+2SD; IL-8)
sensitivity: 0.2 pg/mL
(MinDC+2SD; NGF)
sensitivity: 0.2 pg/mL
(MinDC+2SD; TNF?)
sensitivity: 0.6 pg/mL
(MinDC+2SD; IL-6)
sensitivity: 10 pg/mL
(MinDC+2SD; Leptin)
sensitivity: 15 pg/mL
(MinDC+2SD; Adiponectin)
sensitivity: 2.0 pg/mL
(MinDC+2SD; IL-1?)
sensitivity: 2.1 pg/mL
(MinDC+2SD; MCP-1)
sensitivity: 3.0 pg/mL
(MinDC+2SD; HGF)
sensitivity: 4.4 pg/mL
(MinDC+2SD; Resistin)
sensitivity: 4.6 pg/mL
(MinDC+2SD; PAI-1 (total))
standard curve range: 0.29-4,000 pg/mL
(IL-8)
standard curve range: 0.32-5,000 pg/mL
(NGF)
standard curve range: 0.38-6,000 pg/mL
(TNFα)
standard curve range: 0.51-8,000 pg/mL
(IL-1β)
standard curve range: 0.96-150,000 pg/mL
(IL-6)
standard curve range: 0.96-150,000 pg/mL
(MCP-1)
standard curve range: 26-400,000 pg/mL
(Adipnectin)
standard curve range: 6.4-100,000 pg/mL
(HGF)
standard curve range: 6.4-100,000 pg/mL
(Resistin)
standard curve range: 9.6-150,000 pg/mL
(Leptin)
standard curve range: 9.6-150,000 pg/mL
(PAI-1)
inter-assay cv: <15%
intra-assay cv: <10%
(Adiponectin)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-8)
inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1)
inter-assay cv: <15%
intra-assay cv: <10%
(Resistin)
inter-assay cv: <20%
intra-assay cv: <10%
(HGF)
inter-assay cv: <20%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <20%
intra-assay cv: <10%
(NGF)
inter-assay cv: <20%
intra-assay cv: <10%
(PAI-1 (total))
inter-assay cv: <20%
intra-assay cv: <10%
(TNFα)
inter-assay cv: <20%
intra-assay cv: <15%
(IL-1β)
inter-assay cv: <25%
intra-assay cv: <20%
(Leptin)
技術
multiplexing: suitable
檢測方法
fluorometric (Luminex xMAP)
運輸包裝
wet ice
一般說明
The MILLIPLEX® Human Adipocyte Panel is an 11-plex kit to be used for the simultaneous quantification of any or all of the following analytes in cell/tissue culture samples: Adiponectin, HGF, IL-β, IL-6, IL-8, Leptin, MCP-1, NGF, PAI-1 (total), Resistin, TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
特異性
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
應用
- Analytes: Adiponectin, HGF, IL-1β, IL-6, IL-8, Leptin, MCP-1, NGF, PAI-1 (Total), Resistin, TNF-α
- Recommended Sample Type: Tissue/cell culture supernatants or extracts
- Recommended Sample Dilution: 25 μL per well of undiluted tissue/cell culture sample; samples may require dilution with an appropriate medium prior to assay
- Assay Run Time: Overnight (16-18 hours) at 2-8°C
- Research Category: Metabolism
- Research Subcategory: Endocrine
特點和優勢
包裝
儲存和穩定性
其他說明
法律資訊
免責聲明
訊號詞
Danger
危險分類
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
儲存類別代碼
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
相关内容
Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.
Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.
Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.
Multiplex immunoassays save time and sample volume in metabolic syndrome research, providing comprehensive insights into related conditions.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门