20350

Supelco

ORBO 49P (OVS) Supelpak-20 Amberlitespécialement traité XAD®-2 (20/40), 270/140 mg

RC,GFF,F,F (specially cleaned) separators, O.D. × L 13-8 mm × 75 mm , OSHA Versatile Sampler (OVS) Tube, pkg of 10 ea

Synonyme(s) :

ORBO Supelpak de la série 20, tube

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
47131900

Matériaux

RC,GFF,F,F (specially cleaned) separators

Niveau de qualité

Agence

NIOSH 5601
OSHA 62,63,67,70,74

Gamme de produits

Amberlite
ORBO

Composition

Bed A, 270 mg
Bed B, 140 mg

Conditionnement

pkg of 10 ea

Fabricant/nom de marque

ORBO 49P

Technique(s)

active air sampling: suitable

D.E. × L

13-8 mm × 75 mm , OSHA Versatile Sampler (OVS) Tube

Matrice

XAD-2 (specially cleaned)

Taille des particules

20-40 mesh

Application(s)

air monitoring
environmental
industrial hygiene

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

L′échantillonneur OVS (OSHA Versatile Sampler) a été principalement conçu pour la collecte de pesticides organophosphorés, mais il est adapté pour d′autres applications. Il s′agit d′un tube en verre ouvert spécialement, construit de 75 mm de long et d′un diamètre externe de 13 mm sur l′extrémité d′entrée, qui s′effile à 8 mm (DE) sur l′extrémité de sortie. Ce dispositif comporte un filtre en verre pour piéger les aérosols et une partie sorbante à deux sections pour l′adsorption des vapeurs. Le tube est rempli d′une matière XAD-2 spécialement épurée et est soumis à des tests QA pour garantir une faible interférence liée au bruit de fond. Le tube est muni de bouchons à l′entrée et à la sortie pour minimiser l′exposition à l′environnement. Conformes aux spécifications en matière de conception et de méthode OSHA et NIOSH.

Informations légales

Amberlite is a trademark of DuPont de Nemours, Inc.
ORBO is a trademark of Sigma-Aldrich Co. LLC
Supelpak is a trademark of Sigma-Aldrich Co. LLC
XAD is a registered trademark of The Dow Chemical Company or an affiliated company of Dow

Code de la classe de stockage

10 - Combustible liquids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Désolés, nous n'avons pas de COA pour ce produit disponible en ligne pour le moment.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

F J Egea González et al.
Journal of AOAC International, 80(5), 1091-1097 (1997-11-05)
A method to sample and analyze chlorothalonil and dichlofluanid in greenhouse air was evaluated. Analysis was performed by gas chromatography with electron capture detection and gas chromatography-mass spectrometry. Solid sorbents such as Chromosorb 102, Porapak R, Supelpak-2, Amberlite XAD-2, Amberlite
Nikolaos G Tsiropoulos et al.
Analytica chimica acta, 573-574, 209-215 (2007-08-29)
A methodology is described for greenhouse air analysis by sampling fenhexamid, pyrimethanil, malathion, metalaxyl-M and myclobutanil in solid sorbents. Pesticides were determined by gas chromatography with NP Detector. The trapping efficiency of XAD-2, XAD-4, Supelpak-2, Florisil and C-18 at different
K Flo et al.
Scandinavian journal of clinical and laboratory investigation, 55(8), 715-721 (1995-12-01)
Elevated extracellular cGMP levels have been observed in various clinical conditions, and the analyte has been proposed as a diagnostic marker of cardiovascular as well as malignant diseases. However, the use of extracellular cGMP as a pathophysiological marker requires detailed
A Orbo et al.
Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke, 117(7), 972-976 (1997-03-10)
The development of female steroid hormone-related neoplasms such as gynaecologic and mammary cancers is influenced by hormones administered exogenously. Hormonal contraceptives and hormone replacement therapy both affect the risk of developing cancers in the endometrium, cervix, ovarium, and mammary glands.
Bjørn T Moe et al.
Anticancer research, 29(4), 1047-1052 (2009-05-06)
Endometrial hyperplasia is a precursor lesion of endometrial carcinoma. Clinical studies of endometrial hyperplasia have shown that levonorgestrel (LNG) is more therapeutically effective than medroxyprogesterone acetate (MPA). The present pharmacological in vitro study was performed to compare progestin effects on

Chromatograms

suitable for GC, application for air monitoring

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique