While most HPLC columns feature 10.32 threaded end fittings, some may have different types and sizes of fittings. Given the wide variety of HPLC systems, it is not possible to guarantee with complete certainty that a specific HPLC system utilizes 10.32 fittings. Furthermore, even within a single type of fitting, such as 10.32, there are short, standard, and extended versions of the nut and ferrule. Hence, it is advisable to consult the instrument manual to determine the correct fitting type and size.
Größe auswählen
| Packungsgröße | SKU | Verfügbarkeit | Preis |
|---|
Über diesen Artikel
Produktname
Purospher® STAR NH2 (5 µm), L × I.D. 150 mm x 4.6 mm LiChroCART™ HPLC cartridge, manuCART™ holder required for use
material
stainless steel column
Quality Level
agency
suitable for USP L8
product line
Purospher®
feature
endcapped: no
packaging
1 ea of
extent of labeling
3.5% Carbon loading
parameter
250 bar pressure, 60 °C max. temp.
technique(s)
HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium)
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
Verwandte Kategorien
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| separation technique hydrophilic interaction (HILIC), reversed phase, normal phase | separation technique hydrophilic interaction (HILIC), normal phase, reversed phase | separation technique hydrophilic interaction (HILIC), normal phase, reversed phase | separation technique hydrophilic interaction (HILIC), normal phase, reversed phase |
| matrix active group NH2 bonding phase | matrix active group NH2 bonding phase | matrix active group NH2 bonding phase | matrix active group NH2 bonding phase |
| particle size 5 μm | particle size 5 μm | particle size 5 μm | particle size 5 μm |
| matrix fully porous particle | matrix fully porous particle | matrix fully porous particle | matrix fully porous particle |
| product line Purospher® | product line Purospher® | product line Purospher® | product line Purospher® |
| technique(s) HPLC: suitable, mass spectrometry (MS): suitable (Low - Medium), LC/MS: suitable | technique(s) HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium) | technique(s) HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium) | technique(s) HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium) |
General description
Application
Features and Benefits
- Ultra-pure silica (99.999%)
- Low silanol activity
- Reproducible results from run-to-run and batch-to-batch
Analysis Note
Theoretical Plates (N/m) (2-Nitrotoluene): ≥ 50000
Symmetry (2-Nitrotoluene): 0.8 - 1.4
Capacity factor (2-Nitrotoluene): ≤ 3.0
Legal Information
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Global Trade Item Number
| SKU | GTIN |
|---|---|
| 1502470001 | 04022536752655 |
-
Is the product Purospher® STAR NH2 (5 µm) LiChroCART® 150-4.6 column (catalog number 1.50247.0001 or 48219-474) compatible with the Agilent 1260 HPLC system?
1 answer-
Helpful?
-
Active Filters
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung