Direkt zum Inhalt
Merck

295906

Sigma-Aldrich

Poly(ethylenglykol)

average Mn 2,050, chips

Synonym(e):

PEG

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
H(OCH2CH2)nOH
CAS-Nummer:
MDL-Nummer:
UNSPSC-Code:
12352104
PubChem Substanz-ID:
NACRES:
NA.23

Produktbezeichnung

Poly(ethylenglykol), average Mn 2,050, chips

Form

chips

Qualitätsniveau

Mol-Gew.

average Mn 2,050

mp (Schmelzpunkt)

52-54 °C

Ω-Ende

hydroxyl

α-Ende

hydroxyl

SMILES String

C(CO)O

InChI

1S/C2H6O2/c3-1-2-4/h3-4H,1-2H2

InChIKey

LYCAIKOWRPUZTN-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Anwendung

  • Cytotoxicity Study of Polyethylene Glycol Derivatives: Evaluates the cytotoxic effects of various PEG derivatives, important for chemists in pharmaceutical development and safety assessment (Liu et al., 2017).
  • ExtraPEG: A Polyethylene Glycol-Based Method for Enrichment of Extracellular Vesicles: Introduces a PEG-based method for isolating exosomes, useful for researchers in biomedical and clinical sciences (Rider et al., 2016).

Sonstige Hinweise

Molecular weight: Mn 1,900-2,200

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 1

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Gloves, type N95 (US)


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

Paras R Patel et al.
Journal of neural engineering, 12(4), 046009-046009 (2015-06-03)
Single carbon fiber electrodes (d = 8.4 μm) insulated with parylene-c and functionalized with pTS have been shown to record single unit activity but manual implantation of these devices with forceps can be difficult. Without an improvement in the insertion
Chenlu Zhang et al.
PloS one, 12(9), e0184730-e0184730 (2017-09-09)
The economic production of cellulosic biofuel requires efficient and full utilization of all abundant carbohydrates naturally released from plant biomass by enzyme cocktails. Recently, we reconstituted the Neurospora crassa xylodextrin transport and consumption system in Saccharomyces cerevisiae, enabling growth of
Elissa J Welle et al.
Journal of neural engineering, 17(2), 026037-026037 (2020-03-27)
Carbon fiber electrodes may enable better long-term brain implants, minimizing the tissue response commonly seen with silicon-based electrodes. The small diameter fiber may enable high-channel count brain-machine interfaces capable of reproducing dexterous movements. Past carbon fiber electrodes exhibited both high
Paras R Patel et al.
Journal of neural engineering, 17(5), 056029-056029 (2020-10-16)
Multimodal measurements at the neuronal level allow for detailed insight into local circuit function. However, most behavioral studies focus on one or two modalities and are generally limited by the available technology. Here, we show a combined approach of electrophysiology
Mark A Rice et al.
Acta biomaterialia, 5(1), 152-161 (2008-09-17)
Ultrasound has potential as a non-destructive analytical technique to provide real-time online assessments of matrix evolution in cell-hydrogel constructs used in tissue engineering. In these studies, chondrocytes were encapsulated in poly(ethylene glycol) hydrogels, and gel degradation was manipulated to provide

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.