Alle Fotos(2)
Wichtige Dokumente
254282
Lithiummetaborat
99.995% trace metals basis
Synonym(e):
Boric acid lithium salt
Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise
Alle Fotos(2)
About This Item
Empfohlene Produkte
Qualitätsniveau
Assay
99.995% trace metals basis
Form
powder
Verunreinigungen
≤55.0 ppm Trace Metal Analysis
mp (Schmelzpunkt)
845 °C (lit.)
SMILES String
[Li+].[O-]B=O
InChI
1S/BO2.Li/c2-1-3;/q-1;+1
InChIKey
HZRMTWQRDMYLNW-UHFFFAOYSA-N
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
Verwandte Kategorien
Signalwort
Danger
H-Sätze
Gefahreneinstufungen
Acute Tox. 4 Oral - Eye Dam. 1 - Repr. 2
Lagerklassenschlüssel
13 - Non Combustible Solids
WGK
WGK 1
Flammpunkt (°F)
Not applicable
Flammpunkt (°C)
Not applicable
Persönliche Schutzausrüstung
Eyeshields, Gloves, type N95 (US)
Hier finden Sie alle aktuellen Versionen:
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Applied optics, 48(16), 2979-2982 (2009-06-03)
Efficient cw intracavity frequency doubling of a diode end-pumped Nd:GdVO4 laser that operates in the 4F(3/2) --> 4I(9/2) transition at 912 nm is demonstrated. A 15 mm long lithium borate crystal, cut for critical type I phase matching at room
Analytical chemistry, 73(14), 3410-3416 (2001-07-31)
Americium-241 and plutonium determinations will become of greater importance over the coming decades as 137Cs and 241Pu decay. The impact of 137Cs on environmental chronology has been great, but its potency is waning as it decays and diffuses. Having 241Am
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine, 67(7-8 Suppl), S149-S152 (2009-04-21)
This work provides the basis of a methodology to build a deterministic model for the spatial distribution of the (10)B(n,alpha)(7)Li reaction rate in boron neutron capture therapy (BNCT), as a function of space variables, boron concentration and beam incidence angle
Radiation protection dosimetry, 100(1-4), 211-216 (2002-10-18)
High resolution emission spectra of several TL materials, that are commonly used in dosimetry, were measured using a low cost fibre optic spectrometer containing a 2048 pixel CCD array. The spectra were taken from 177 to 890 nm with a
Journal of endourology, 26(4), 313-317 (2012-03-24)
The goal of this study is to identify the most efficient sweeping angle (SA) during photoselective vaporization of the prostate (PVP). Experiments were conducted with GreenLight XPS™ laser at 120 and 180 W. Ten blocks of porcine kidney were used for
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.