These columns are end-capped, but the phase is cyanopropyl.
₩1,373,498
출고 가능일2025년 4월 21일세부사항
추천 제품
제품명
Discovery® Cyano HPLC Column, 5 μm particle size, L × I.D. 15 cm × 4.6 mm
material
stainless steel column
Quality Level
Agency
suitable for USP L10
제품 라인
Discovery®
특징
endcapped
제조업체/상표
Discovery®
포장
1 ea of
라벨링 범위
4.5% Carbon loading
파라미터
≤70 °C temp. range
400 bar pressure (5801 psi)
기술
HPLC: suitable
LC/MS: suitable
길이 × I.D.
15 cm × 4.6 mm
표면적
200 m2/g
표면 범위
3.5 μmol/m2
불순물
<10 ppm metals
Matrix
silica gel, high purity, spherical base material
fully porous particle
기질 활성군
cyano phase
입자 크기
5 μm
공극 크기
180 Å
작동 pH 범위
2-8
응용 분야
food and beverages
분리 기술
hydrophilic interaction (HILIC)
normal phase
reversed phase
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
특징 및 장점
- Low hydrophobicity for rapid elution of hydrophobic analytes
- Excellent peak shape and retention of strongly basic analytes
- Retention of polar analytes
- Unique selectivity
- Significantly less retention than C18 (typically requires lower % organic mobile phase)
- Stable, low-bleed LC-MS separations
- Compatible with highly aqueous organic phases
법적 정보
Storage Class Code
13 - Non Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
-
¿Me podrías confirmar que la composición de esta columna es end-capped cyanosilyl silica gel for chromatography R? Gracias!
1 답변-
도움이 되었습니까?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 답변-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
도움이 되었습니까?
-
-
How can I determine the shelf life / expiration / retest date of this product?
1 답변-
If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf도움이 되었습니까?
-
-
Please provide the below details for the column Carbon loading%- Pore size- Surface area- pH stability- End capping-
1 답변-
TS Answer:
- 4.5% Carbon loading
- Pore size: 180 Å
- Surface area: 200 m2/g
- Operating pH range: 2-8
- Endcapped
- Particle Size: 5 μm
- Temperature Range: ≤70 °C
- Maximum Pressure: 400 bar pressure (5801 psi)
- Suitable for USP L10도움이 되었습니까?
-