57281-U

Supelco

SPME LC Fiber Probe, C18

df 45 μm(C18, pkg of 5 ea

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41115724
NACRES:
NB.21

material

metal alloy fiber
plain red hub

니들 크기

22 ga

포장

pkg of 5 ea

df

45 μm (C18)

기술

solid phase microextraction (SPME): suitable

니들 길이

25 mm (1 in.)

기질 활성군

C18 coating

응용 분야

food and beverages

호환성

for use with solvent desorption

분리 기술

reversed phase

일반 설명

The SPME-LC fiber probes are intended as single-use devices for the extraction of small molecules out of a fluid followed by solvent desorption and LC analysis.

가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

Xu Zhang et al.
Journal of chromatography. A, 1216(45), 7664-7669 (2009-09-22)
Solid-phase microextraction (SPME) has been demonstrated to be useful for in vivo sampling in pharmacokinetic studies. In this study, a single time-point kinetic calibration for in vivo dynamic monitoring was developed by simplification of the laborious multiple time-point kinetic calibration
Dajana Vuckovic et al.
Journal of chromatography. A, 1217(25), 4041-4060 (2009-12-25)
The primary objective of this review is to discuss recent technological developments in the field of solid-phase microextraction that have enhanced the utility of this sample preparation technique in the field of bioanalysis. These developments include introduction of various new
Joanne Chung Yan Yeung et al.
Analytica chimica acta, 665(2), 160-166 (2010-04-27)
The success of in vivo solid phase microextraction (SPME) depends significantly on the selection of calibration method. Three kinetic in vivo SPME calibration methods are evaluated in this paper: (1) on-fibre standardization (OFS), (2) dominant pre-equilibrium desorption (DPED), and (3)
Metabolic Profiling of Plasma from Cardiac Surgical Patients Concurrently Administered with Tranexamic Acid: DI-SPME?LC?MS Analysis
Bojko, B., et al.
Journal of Pharmaceutical Analysis, 4 (1), 6-13 (2014)
Hiroyuki Kataoka et al.
Journal of pharmaceutical and biomedical analysis, 54(5), 926-950 (2011-01-05)
Biomedical analyses of drugs, metabolites, poisons, environmental and occupational pollutants, disease biomarkers and endogenous substances in body fluids and tissues are important in the development of new drugs, therapeutic monitoring, forensic toxicology, patient diagnosis, and biomonitoring of human exposure to

문서

Biocompatible SPME devices employ C18 bonded porous silica sorbent particles, in a binder which resists fouling by biological matrix components

Accurate protein binding affinities were measured using bioSPME more rapidly than membrane dialysis (RED) techniques. Binding affinities correlated to the reference values.

관련 콘텐츠

A demonstration of the use of innovative BioSPME fibers for the selective extraction of drugs and polar metbolites from biological matrices.

질문

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.