Supelco

SLB®-IL111 Capillary GC Column

L × I.D. 200 m × 0.25 mm, df 0.20 μm

로그인조직 및 계약 가격 보기

크기 선택

1 EA
₩5,574,177

₩5,574,177


구입 가능 여부는 고객센터에 문의하십시오.


크기 선택

보기 변경
1 EA
₩5,574,177

About This Item

UNSPSC 코드:
41115710
NACRES:
SB.54

₩5,574,177


구입 가능 여부는 고객센터에 문의하십시오.

material

fused silica

Quality Level

파라미터

50-270 °C temperature (isothermal or programmed)

베타 값

313

df

0.20 μm

기술

gas chromatography (GC): suitable

길이 × I.D.

200 m × 0.25 mm

기질 활성군

Non-bonded; 1,5-Di(2,3-dimethylimidazolium)pentane bis(trifluoromethanesulfonyl)imide phase

응용 분야

agriculture
biofuels
chemicals and industrial polymers
clinical
environmental
food and beverages
petroleum

컬럼 유형

capillary extremely polar

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Application: World′s first commercial column to rate over 100 on our GC column polarity scale. Selectivity most orthogonal to non-polar and intermediate polar phases, resulting in very unique elution patterns. Maximum temperature of 270 ºC is very impressive for such an extremely polar column. Great choice for separation of polarizable analytes (contain double and/or triple C-C bonds) from neutral analytes. Also a good GCxGC column choice. Launched in 2010.
USP Code: None
Phase:
  • Non-bonded
  • 1,5-Di(2,3-dimethylimidazolium)pentane bis(trifluoromethylsulfonyl)imide
Temp. Limits:
  • 50 °C to 270 °C (isothermal or programmed)

애플리케이션

Fast GC Analysis of Fatty Acid Methyl Esters Using a Highly Polar Ionic Liquid Column and its Application for the Determination of Trans Fatty Acid Contents in Edible Oils
This study presents a rapid method for analyzing trans fatty acid contents in edible oils using a fast gas chromatography (GC) technique combined with a highly polar ionic liquid column. The method significantly reduces analysis time to under 30 minutes, compared to over 90 minutes required by traditional methods from the American Oil Chemists’ Society (AOCS) and Japanese Oil Chemists’ Society (JOCS). The effectiveness of the fast GC method was confirmed through comparisons of trans fatty acid content in various oils, showing good agreement with results from the official methods. The study highlights the advantages of using m-TFPTAH for methyl esterification, which streamlines the process and enhances throughput.
Shinsuke Inagaki, Masahiko Numata (2015) https://doi.org/10.1007/s10337-014-2837-z

법적 정보

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Michelle S S Amaral et al.
Analytical and bioanalytical chemistry, 410(19), 4615-4632 (2017-11-12)
This study investigates applications and performance evaluation of SLB-IL60, SLB-IL76 and SLB-IL111 columns, in relation to a DB-Wax column, for the analysis of coffee volatile compounds. Both standards and an authentic coffee sample were analysed, with solid-phase microextraction (SPME) sampling

프로토콜

Ionic liquid capillary GC columns enhance polar analyte inertness, addressing challenges in chromatography with improved stationary phases.

질문

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.