콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

20257-U

Supelco

ORBO 23 2-HMP on Amberlite XAD®-2 (20/40), 120/60 mg

W,W,W separators, O.D. × L 6 mm × 85 mm, pkg of 25 ea

동의어(들):

ORBO 2-HMP on Supelpak 20N Tube

로그인조직 및 계약 가격 보기

크기 선택

25 EA
₩495,828

₩495,828


구입 가능 여부는 고객센터에 문의하십시오.

벌크 견적 요청

크기 선택

보기 변경
25 EA
₩495,828

About This Item

UNSPSC 코드:
12190000
NACRES:
NB.24

₩495,828


구입 가능 여부는 고객센터에 문의하십시오.

벌크 견적 요청

material

W,W,W separators

Agency

NIOSH 2501,2529,2536,2539,2541

제품 라인

Amberlite
ORBO

구성

Bed A, 120 mg
Bed B, 60 mg

포장

pkg of 25 ea

제조업체/상표

ORBO 23

기술

active air sampling: suitable

O.D. × L

6 mm × 85 mm

Matrix

XAD-2 2-(Hydroxymethyl)piperidine on XAD-2

입자 크기

20-40 mesh

응용 분야

air monitoring
environmental
industrial hygiene

저장 온도

2-8°C

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

ORBO 23 2-HMP on Amberlite XAD®-2 (20/40), 120/60 mg sorbent tubes (W,W,W separators, O.D. × L 6 mm × 85 mm) contain two beds of the same selective adsorbent separated by glass wool or foam, for gas and vapor sampling. The dual-layer or two-bed construction of the tube allows for any sample breakthrough to be captured in the smaller back-up bed.

법적 정보

Amberlite is a trademark of DuPont de Nemours, Inc.
ORBO is a trademark of Sigma-Aldrich Co. LLC
Supelpak is a trademark of Sigma-Aldrich Co. LLC
XAD is a registered trademark of The Dow Chemical Company or an affiliated company of Dow

픽토그램

Corrosion

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Eye Dam. 1 - Skin Corr. 1B

Storage Class Code

8A - Combustible corrosive hazardous materials

WGK

WGK 3


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

F J Egea González et al.
Journal of AOAC International, 80(5), 1091-1097 (1997-11-05)
A method to sample and analyze chlorothalonil and dichlofluanid in greenhouse air was evaluated. Analysis was performed by gas chromatography with electron capture detection and gas chromatography-mass spectrometry. Solid sorbents such as Chromosorb 102, Porapak R, Supelpak-2, Amberlite XAD-2, Amberlite
Anne Ørbo et al.
The Journal of steroid biochemistry and molecular biology, 113(1-2), 139-149 (2009-01-14)
Patients with endometrial hyperplasia representing preliminary stages of endometrial cancer have shown to respond to therapy in 100% of the cases when treated with levonorgestrel-impregnated intrauterine device. Anti-proliferative effect has also been reported after application of an anti-progestin impregnated intrauterine
H Stalsberg et al.
Virchows Archiv. A, Pathological anatomy and histopathology, 414(5), 415-422 (1989-01-01)
The autopsies of 12 victims from two snow avalanches in North-Norway are reported. Supportive evidence from non-autopsied and surviving victims is included. Consistent autopsy findings were prominent lung oedema, moderate cerebral oedema, extreme contraction of the left ventricle, petechiae in
Anne Beate Vereide et al.
Gynecologic oncology, 97(3), 740-750 (2005-05-12)
The aim of the study was to investigate apoptosis as a growth regulatory mechanism of gestagen in endometrial precancers and to compare differences in the apoptotic cascade after high and low dose gestagen regimens. Pre- and post-treatment paraffin-embedded endometrial hyperplasia
Bjørn T Moe et al.
Anticancer research, 29(4), 1047-1052 (2009-05-06)
Endometrial hyperplasia is a precursor lesion of endometrial carcinoma. Clinical studies of endometrial hyperplasia have shown that levonorgestrel (LNG) is more therapeutically effective than medroxyprogesterone acetate (MPA). The present pharmacological in vitro study was performed to compare progestin effects on

질문

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.