콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

S5393

Sigma-Aldrich

Serum minus IgA/IgM/IgG human

lyophilized powder

동의어(들):

Depleted Serum

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12352203
NACRES:
NA.46

생물학적 소스

human

Quality Level

결합

unconjugated

형태

lyophilized powder

포함

15 mM sodium azide

포장

vial of 0.5 mL

저장 온도

2-8°C

타겟 번역 후 변형

unmodified

일반 설명

Serum is the liquid component of blood that includes proteins, immunoglobulin and electrolytes. The product can be used for selective removal of contaminating antibodies when immobilized on a solid matrix. This product can also be used in anti-protective antigen (anti-PA) IgG measurements using PA coupled microspheres. Human serum deficient of IgG, IgA, and IgM can react specifically with anti-human whole serum but does not show reactivity with anti-human IgG, IgA, or IgM.

애플리케이션

Serum minus IgA/IgM/IgG human has been used as a control serum in immunoelectrophoresis, immunodiffusion,enzyme linked immunosorbent assay. It has also been used as
  • control sera to assess neuraminidase inhibition
  • microneutralization assay
  • single radial hemolysis (SRH) repeatability assay

수량

Each vial contains at least 25 mg protein

재구성

Reconstitute with 0.5 mL deionized water.

면책조항

RESEARCH USE ONLY. This product is regulated in France when intended to be used for scientific purposes, including for import and export activities (Article L 1211-1 paragraph 2 of the Public Health Code). The purchaser (i.e. enduser) is required to obtain an import authorization from the France Ministry of Research referred in the Article L1245-5-1 II. of Public Health Code. By ordering this product, you are confirming that you have obtained the proper import authorization.

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Storage Class Code

10 - Combustible liquids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Fabrizio Biuso et al.
Influenza and other respiratory viruses, 13(5), 504-516 (2019-08-15)
Formulation of neuraminidase (NA) within influenza vaccines is gaining importance in light of recent human studies. The enzyme-linked lectin assay (ELLA) is considered a reliable assay to evaluate human anti-NA antibodies. To overcome interference by hemagglutinin (HA)-specific antibodies and detect
Karina Jawinski et al.
Frontiers in immunology, 10, 2661-2661 (2019-12-05)
Current influenza vaccines manufactured using eggs have considerable limitations, both in terms of scale up production and the potential impact passaging through eggs can have on the antigenicity of the vaccine virus strains. Alternative methods of manufacture are required, particularly
Raymond E Biagini et al.
Clinical and diagnostic laboratory immunology, 10(5), 744-750 (2003-09-11)
We describe a fluorescent covalent microsphere immunoassay (FCMIA) method for the simultaneous (multiplexed) measurement of immunoglobulin G (IgG) antibodies to 23 pneumococcal capsular polysaccharide (PnPS) serotypes present in the pneumococcal polysaccharide vaccine (PPV23) licensed by the Food and Drug Administration
Thorunn A Olafsdottir et al.
Frontiers in immunology, 8, 1872-1872 (2018-01-24)
Influenza vaccination remains the best strategy for the prevention of influenza virus-related disease and reduction of disease severity and mortality. However, there is large individual variation in influenza vaccine responses. In this study, we investigated the effects of gender, age
Validation of Single Radial Haemolysis assay: A reliable method to measure antibodies against influenza viruses
Trombetta CM, et al.
Journal of Immunological Methods, 422, 95-101 (2015)

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.