콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

L9529

Sigma-Aldrich

Latex beads, amine-modified polystyrene, fluorescent orange

aqueous suspension, 2.0 μm mean particle size

로그인조직 및 계약 가격 보기

크기 선택

1 ML
₩155,803

₩155,803


구입 가능 여부는 고객센터에 문의하십시오.


크기 선택

보기 변경
1 ML
₩155,803

About This Item

MDL number:
UNSPSC 코드:
12352116
NACRES:
NA.56

₩155,803


구입 가능 여부는 고객센터에 문의하십시오.

양식

aqueous suspension

구성

Solids, 2.4-2.6%

평균 입자 크기

2.0 μm

형광

λex ~520 nm; λem ~540 nm

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

Latex beads, amine-modified polystyrene, fluorescent orange has been used in functionalized microbeads for rapid antimicrobial susceptibility testing (AST) evaluation.[1][2] It has also been used in microparticle functionalization for the detection of live bacteria.[3]

생화학적/생리학적 작용

Amine-modified polystyrene latex beads have been used to develop an electrochemical nitrite nanosensor as well as to validate a pharyngeal aspiration technique for exposing the mouse lung to respirable particles.

Storage Class Code

10 - Combustible liquids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

J Geys et al.
Toxicology letters, 160(3), 218-226 (2005-09-03)
Recent studies indicate that inhaled ultrafine particles can pass into the circulation. To study this translocation in an in vitro model three types of pulmonary epithelial cells were examined. The integrity of the cell monolayer was verified by measuring the
Development of a self-driving bioassay based on diffusion for simple detection of microorganisms
Wang J C, et al.
Sensors and Actuators B, Chemical, 278, 140-146 (2019)
Jhih-Cheng Wang et al.
ACS sensors, 3(10), 2182-2190 (2018-09-18)
Rapid detection of bacteria and their susceptibility to specific antibiotics plays a vital role in microbial infection treatments. Antimicrobial susceptibility testing (AST) is a common measure to select effective drugs. However, the conventional practices, such as broth dilution, E-test, and
G V S Rao et al.
Journal of toxicology and environmental health. Part A, 66(15), 1441-1452 (2003-07-15)
Recent studies have demonstrated that the mouse lung can be exposed to soluble antigens by aspiration of these antigens from the pharynx. This simple technique avoids the trauma associated with intratracheal instillation. In this study, the pharyngeal aspiration technique was
Ninad Mehendale et al.
Biomedical microdevices, 20(1), 6-6 (2017-12-01)
Pillar-based microfluidic sorting devices are preferred for isolation of rare cells due to their simple designs and passive operation. Dead-end pillar filters can efficiently capture large rare cells, such as, circulating tumor cells (CTCs), nucleated red blood cells (NRBCs), CD4

질문

  1. The specified output emission is 540nm, which is green. However, the beads are labelled "yellow to orange". When exciting with green I detect fluorescence at 600nm on my spectrometer, which is yellow to orange. Is 540 the actual expected emission? or 600?

    1 답변
    1. The excitation range for this product is 470 nm to 525 nm, and the emission range is 535 nm to 650 nm.

      도움이 되었습니까?

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.