추천 제품
Grade
analytical standard
기술
HPLC: suitable
gas chromatography (GC): suitable
mp
118-120 °C
형식
neat
SMILES string
CN[C@@H](C)[C@@H](O)c1ccccc1
InChI
1S/C10H15NO/c1-8(11-2)10(12)9-6-4-3-5-7-9/h3-8,10-12H,1-2H3/t8-,10+/m0/s1
InChI key
KWGRBVOPPLSCSI-WCBMZHEXSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
(+)-Pseudoephedrine may be used as a reference standard in the determination of pseudoephedrine in pharmaceutical formulations using high performance thin layer chromatography (HPTLC).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
생화학적/생리학적 작용
Non-selective adrenergic agonist; decongestant
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Oral - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
dust mask type N95 (US), Eyeshields, Gloves
이미 열람한 고객
Stability indicating HPTLC method for the simultaneous determination of pseudoephedrine and cetirizine in pharmaceutical formulations.
Makhija N S and Vavia R P.
Journal of Pharmaceutical and Biomedical Analysis, 25(3-4), 663-667 (2001)
Pablo Vazquez-Roig et al.
The Science of the total environment, 494-495, 49-57 (2014-07-17)
The enantiomeric and diastereomeric profiling of chiral pharmaceuticals (ephedrine, norephedrine, atenolol and venlafaxine) and illicit drugs (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxy-N-methylamphetamine (MDMA) and 3,4-methylenedioxy-N-ethylamphetamine (MDEA)) was undertaken over a period of fourteen consecutive days in three wastewater treatment plants (WWTPs)
Sian E Evans et al.
Analytica chimica acta, 882, 112-126 (2015-06-05)
This is the first study presenting a multi-residue method allowing for comprehensive analysis of several chiral pharmacologically active compounds (cPACs) including beta-blockers, antidepressants and amphetamines in wastewater and digested sludge at the enantiomeric level. Analysis of both the liquid and
Aurélie Periat et al.
Journal of chromatography. A, 1356, 211-220 (2014-07-16)
In this study, the influence of electrospray ionization (ESI) source design on the overall sensitivity achieved in hydrophilic interaction chromatography (HILIC) and reversed phase liquid chromatography (RPLC), was investigated. State-of-the-art triple quadrupole mass analyzers from AB Sciex, Agilent Technologies and
Kristiane de Cássia Mariotti et al.
Journal of analytical toxicology, 38(7), 432-437 (2014-07-21)
Brazil is considered one of the countries with the highest number of amphetamine-type stimulant (ATS) users worldwide, mainly diethylpropion (DIE) and fenproporex (FEN). The use of ATS is mostly linked to diverted prescription stimulants and this misuse is widely associated
Chromatograms
application for HPLC자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.