추천 제품
분석
≥95%
SMILES string
[I-].CCCCCN1C(\Oc2ccccc12)=C\C=C\c3oc4ccccc4[n+]3CCCCC
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Probe for measuring membrane potential and localization of endoplasmic reticulum
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Repr. 1B - Skin Irrit. 2 - STOT SE 3
Storage Class Code
6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type P2 (EN 143) respirator cartridges
가장 최신 버전 중 하나를 선택하세요:
The Journal of biological chemistry, 265(19), 10959-10967 (1990-07-05)
The chemotactic peptide formylmethionyl-leucyl-phenylalanine (fMLP), at concentrations below 10(-9) M, elicits a sustained increase in the human neutrophil's membrane potential within 10 s of its addition. This hyperpolarization, detected with the fluorescent cationic potentiometric probes, 3,3'-dipentyloxacarbocyanine (diO-C5-(3)), and 1,1'-dipropyl-3,3,3',3'-tetramethylindocarbocyanine iodide
The Journal of antimicrobial chemotherapy, 43(2), 227-232 (2001-03-17)
A flow cytofluorometric susceptibility test (FCST) was used for rapid determination of the susceptibility of Candida lusitaniae isolates to amphotericin B. The test is based on the decrease in fluorescence intensity of cells stained with 3,3'-dipentyloxacarbocyanine iodide (DiOC5(3)), a membrane
Histochemistry, 84(4-6), 609-613 (1986-01-01)
The measurement of time correlated intracellular mitochondrial staining with 3,3'-dipentyloxacarbocyanine [Di-O-C5(3)] appeared of interest to define the optimal staining conditions. Mitochondrial staining of lymphocytes, monocytes and granulocytes results in different fluorescence signals, related to the numbers of mitochondria, that are
Toxicology and applied pharmacology, 234(3), 300-305 (2008-11-26)
Perfluorinated (aliphatic) acids (PFAs) and congeners have many applications in various industrial fields and household for decades. Years later they have been detected in wildlife and this has spurred interest in environmental occurrence as well as influencing living organisms. PFAs
The American journal of pathology, 118(1), 116-127 (1985-01-01)
Defective phagocytic cell function may partially account for the morbidity and mortality associated with thermal injury. In experimental thermal injury in the rat, small circulating blood volumes increase the difficulty in obtaining significant data. Furthermore, purification and or elicitation procedures
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.