추천 제품
Quality Level
사용
kit sufficient for 200 tests (of 1 mL cell suspensions)
kit sufficient for 40 tests (of 5 mL cell suspensions)
포장
pkg of 1 kit
저장 조건
dry at room temperature
기술
flow cytometry: suitable
protein staining: suitable
형광
λex 490 nm; λem 530 nm (green) (JC-1 monomers)
λex 525 nm; λem 590 nm (red) (JC-1 aggregates)
응용 분야
cell analysis
detection
검출 방법
fluorometric
배송 상태
wet ice
저장 온도
2-8°C
일반 설명
In normal cells, the JC-1 dye concentrates in the mitochondrial matrix where it forms red fluorescent aggregates. Any event that dissipates the mitochondrial membrane potential (e.g. apoptosis) prevents the accumulation of the JC-1 dye in the mitochondria and thus, the dye is dispersed throughout the entire cell leading to a shift from red (JC-1-aggregates) to green fluorescence (JC-1 monomers). The fluorescence of the cells stained with this kit may be observed by fluorescence microscopy or measured by fluorimetric and flow cytometry analysis.
애플리케이션
The dissipation of the mitochondrial electrochemical potential gradient (Δψ) is known as an early event in apoptosis. This kit offers a fast and convenient method for the detection of changes in mitochondrial inner-membrane electrochemical potential in living cells using the cationic, lipophilic dye, JC-1.
특징 및 장점
Kit offers:
- A fast, simple, and convenient method for staining and assaying mitochondria intactness
- Contains all the reagents required for the detection of changes mitochondrial inner-membrane electrochemical potential
- Contains the antibiotic valinomycin, which can be used as a control agent that prevents JC-1 aggregation
- The shift in fluorescence is clearly detectable in both green and red channels
- Suitable for adherent cells as well as cells in suspension
- Has been tested with Jurkat, U-937, HeLa, NIH3T3 cells
- The fluorescence signal can be observed by fluorescence microscopy or measured by flow cytometry
키트 구성품 전용
제품 번호
설명
- DMSO 1 mL
- JC Staining Buffer 5X 120 mL
- JC-1 1 mg
- Valinomycin Ready Made .1 mL
Storage Class Code
10 - Combustible liquids
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
PloS one, 14(4), e0214586-e0214586 (2019-04-02)
Many cells are cultured in media that contains an antibiotic to prevent bacterial contamination. Mycoplasma and other bacterial contamination is a serious problem for those involved in cell culture. Antibiotics in the media helps prevent this contamination and make life
Biochemical and biophysical research communications, 197(1), 40-45 (1993-11-30)
A new method for the cytofluorimetric analysis of mitochondrial membrane potential in intact cells has been developed by using the lipophilic cationic probe 5,5',6,6'-tetrachloro-1,1',3,3'-tetraethylbenzimidazolcarbocyanine iodide (JC-1), whose monomer emits at 527 nm after excitation at 490 nm. Depending on the
Biology of reproduction, 95(4), 82-82 (2016-09-02)
Luteolin is a natural compound known for its anticancer effects on various human cancers by regulating signal transduction cascades. However, the effects of luteolin on human placental choriocarcinoma are not known. Results of the present study revealed that luteolin decreased
Frontiers in genetics, 6, 78-78 (2015-03-31)
Mutations in PARK2, encoding Parkin, cause an autosomal recessive form of juvenile Parkinson Disease (JPD). The aim of the present study was to investigate the impact of PARK2 mutations on mitochondrial function and morphology in human skin fibroblasts. We analyzed
Journal of cellular biochemistry, 119(9), 7377-7387 (2018-05-16)
Formononetin is an isoflavone that is extracted from red clovers or soy. It has anti-oxidant, anti-proliferative, and anti-tumor effects against cells in various diseases. Several cohort studies have indicated that phytoestrogen intake, including formononetin, could reduce the risk of various
문서
Cellular oxidative stress is countered by enzymatic scavengers and antioxidant modulators against reactive oxygen species damage.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.