Histopaque®-1119

sterile-filtered, density: 1.119 g/mL

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12352207
NACRES:
NA.75

무균

sterile-filtered

형태

liquid

유통기한

Expiry date on the label.

불순물

endotoxin, tested

density

1.119 g/mL

응용 분야

hematology
histology

저장 온도

2-8°C

일반 설명

Histopaque®-1119 is a sterile, endotoxin tested, ready-to-use medium. This solution consists of polysucrose and sodium diatrizoate, adjusted to a density of 1.119 g/mL and pH 8.8–9.0.

애플리케이션

Histopaque®-1119 is suitable for use in conjunction with Histopaque-1077 as it facilitates the rapid recovery of viable mononuclear cells and granulocytes from small volumes of whole blood or bone marrow

특징 및 장점

Histopaque®-1119 offers numerous advantages, such as:
  • Optimal recovery of viable cells
  • Permits selective separation of blood cell types
  • Prevents cell distortion
  • Preserves cell viability
  • Minimal extraneous cell interference
  • Reproducible performance from batch to batch
  • Sterile-filtered and endotoxin-tested
  • Stable at 2-8°C for at least 2 years when protected from light

원리

The process involves the formation of a double gradient on layering an equal volume of Histopaque-1077 over Histopaque-1119. Anticoagulated whole blood is carefully layered onto the upper Histopaque-1077 medium. Upon centrifugation, the erythrocytes are aggregated by polysucrose and thus rapidly sediment. Granulocytes are found at the lower Histopaque-1077/1119 interface; whereas, lymphocytes and other mononuclear cells are found at the upper plasma/Histopaque-1077 interface. Most extraneous platelets found in the upper interface are removed by low-speed centrifugation during washing steps. Erythrocyte contamination is negligible.

법적 정보

Histopaque is a registered trademark of Merck KGaA, Darmstadt, Germany

관련 제품

제품 번호
설명
가격

픽토그램

Corrosion

신호어

Warning

유해 및 위험 성명서

Hazard Classifications

Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2

Storage Class Code

8A - Combustible corrosive hazardous materials

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

Darin Quach et al.
Journal of bacteriology, 191(7), 2023-2032 (2008-12-31)
Group B Streptococcus (GBS) is major cause of invasive disease in newborn infants and the leading cause of neonatal meningitis. To gain access to the central nervous system (CNS), GBS must not only subvert host defenses in the bloodstream but
Yuan Li et al.
BMC genomics, 16, 369-369 (2015-05-10)
Understanding genetic determinants of a microbial phenotype generally involves creating and comparing isogenic strains differing at the locus of interest, but the naturally existing genomic and phenotypic diversity of microbial populations has rarely been exploited. Here we report use of
Michael Molitor et al.
Cardiovascular research, 117(1), 162-177 (2020-02-23)
Heart failure (HF) ensuing myocardial infarction (MI) is characterized by the initiation of a systemic inflammatory response. We aimed to elucidate the impact of myelomonocytic cells and their activation by angiotensin II on vascular endothelial function in a mouse model
Ulrich Flögel et al.
Circulation, 118(2), 140-148 (2008-06-25)
In this study, we developed and validated a new approach for in vivo visualization of inflammatory processes by magnetic resonance imaging using biochemically inert nanoemulsions of perfluorocarbons (PFCs). Local inflammation was provoked in 2 separate murine models of acute cardiac
A Bansal et al.
Journal of developmental origins of health and disease, 10(2), 164-175 (2018-10-27)
Exposure to the endocrine disruptor bisphenol A (BPA) is ubiquitous and associated with health abnormalities that persist in subsequent generations. However, transgenerational effects of BPA on metabolic health are not widely studied. In a maternal C57BL/6J mice (F0) exposure model

문서

Centrifugation enables the separation of particles by sedimentation. Learn how to separate particles using a centrifuge and how to use Stokes' law to calculate the velocity of sedimentation.

프로토콜

This troubleshooting guide addresses the most common sources of error observed when using Histopaque but is not meant to be a comprehensive list.

Ficoll 400® is a non-ionic polymer with high hydrophilicity and water solubility, suitable for various biological applications.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.