콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

73108

Supelco

Elemental Impurities according to ICH Q3D oral, Standard 2

TraceCERT®, (in 10% hydrochloric acid), applicable for testing acc. to USP<232>, Ph.Eur. Gen. Chapter 5.20

동의어(들):

ICH Q3D Elemental Impurity Analysis

로그인조직 및 계약 가격 보기

크기 선택

100 ML
₩642,800

₩642,800


구입 가능 여부는 고객센터에 문의하십시오.

벌크 견적 요청

크기 선택

보기 변경
100 ML
₩642,800

About This Item

UNSPSC 코드:
41116107
NACRES:
NA.24

₩642,800


구입 가능 여부는 고객센터에 문의하십시오.

벌크 견적 요청

Grade

certified reference material

Quality Level

Agency

according to ICH Q3D
according to Ph. Eur.
according to USP

제품 라인

TraceCERT®

grade

TraceCERT®

유통기한

limited shelf life, expiry date on the label

구성

Au, 100 mg/L
Ir, 100 mg/L
Os, 100 mg/L
Pd, 100 mg/L
Pt, 100 mg/L
Rh, 100 mg/L
Ru, 100 mg/L

농도

(in 10% hydrochloric acid)

기술

ICP: suitable

형식

multi-component solution

일반 설명

This certified reference material (CRM) is produced in accordance with ISO 17034 and characterized in accordance with ISO/IEC 17025. This CRM is traceable to SI unit kg and measured against primary material from a National Metrology Institute (NMI), e.g. NIST.

Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.

Download your certificate at https://www.sigma-aldrich.com to view certified values, including uncertainty, date of expiry, and detailed information about trace impurities.

제조 메모

For the preparation of this CRM only materials of highest purity were used.

기타 정보

We provide a diverse range of certified reference materials, including various elemental impurity mixes and single elements, with concentration limits that comply with ICH Q3D guidelines. For more information please visit our Inorganic Elemental Impurity Mix Standards.

In our effort to be more sustainable, we′re going digital with COAs-download them directly from our website.

법적 정보

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

픽토그램

CorrosionExclamation mark

신호어

Warning

유해 및 위험 성명서

Hazard Classifications

Met. Corr. 1 - Skin Irrit. 2 - STOT SE 3

표적 기관

Respiratory system

Storage Class Code

8B - Non-combustible corrosive hazardous materials

WGK

WGK 1

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

문서

Control elemental impurities in drug products with analytical methods and materials to ensure patient safety.

질문

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.