The recommended alternative product is S2GPU05RE, Stericup Quick Release-GP Sterile Vacuum Filtration System from Millipore. This system includes a 500 mL Steritop bottle top filter unit utilizing a 0.22 µm pore size fast flow PES Express PLUS membrane, along with a 500 mL receiver flask for the sterilization of tissue culture media, protein, and DNA.
S2GPU05RE
Millipore® Stericup® Quick Release Vacuum Filtration System
pore size 0.22 μm, polyethersulfone membrane, funnel capacity 500 mL, pack of 12 ea
동의어(들):
SCGPU05RE, Stericup Quick Release-GP Sterile Vacuum Filtration System, sterile vacuum filter unit, sterile vacuum filtering unit, vacuum filtration system
크기 선택
About This Item
추천 제품
material
polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing
Quality Level
무균
sterile; irradiated
제품 라인
Stericup®
특징
hydrophilic
포장
pack of 12 ea
파라미터
45 °C max. temp.
설명
2.4 mL (hold-up volume)
기술
sterile filtration: suitable
높이
263 mm
용량
500 mL
직경
12.5 cm
필터 직경
73 mm
여과 면적
40 cm2
깔대기 용량
500 mL
Matrix
Express PLUS™
공극 크기
0.22 μm pore size
피팅
inlet funnel
outlet flask (Receiver)
배송 상태
ambient
일반 설명
애플리케이션
- Tissue culture media +/- additives
- Buffers
- Biological solutions
특징 및 장점
- The Quick Release filter funnel disconnects from the receiver bottle with just a quarter turn—reducing the likelihood of spillage and making it easier to manipulate on the bench or under the hood.
- Bold product identification on the Steritop® filter funnel plainly displays membrane characteristics, including composition and pore size, for rapid, application-appropriate product selection.
- Click seal cap is flanged and modified to enable a firm grip in wet or dry conditions—and a tactile stop confirms secure closure. Worry less about the possibility of spilling or contamination of sterilized contents.
- Frosted, ample writing surface on the receiver bottle and lighter cap color facilitate clear labelling to improve legibility and reduce unreadable smears.
- Click seal cap rests on the side to avoid risk of contamination.
- Receiver bottles are stackable to save storage space.
법적 정보
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
문서
Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.
Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.
Ensure optimal cell culture outcomes with ultrapure, endotoxin-free water. Learn about the impact of water impurities on mammalian cell cultures and how to achieve optimal cell growth.
Overview on how to maintain proper cell culture laboratory safety including steps on performing lab risk assessments, surface disinfection, biohazard and waste removal. Free ECACC handbook download.
관련 콘텐츠
What are you filtering out? What do you want to keep? Pick the right membrane for your filtration.
Learn how to effectively filter fetal bovine serum (FBS) using Stericup® Quick Release vacuum filtration devices, including flow test data and analysis.
This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.
-
What is the Corning alternative for the product CLS431097, which is a Corning® bottle-top vacuum filter system with specific features like a polyethersulfone membrane, pore size of 0.22 μm, membrane area of 33.2 cm2, and a filter capacity of 500 mL?
1 답변-
도움이 되었습니까?
-
-
Can Stericup® and Steritop® filters be reused?
1 답변-
All Stericup® and Steritop® filters were developed for single use, disposable processing.
도움이 되었습니까?
-
-
Can Stericup® bottles be placed inside freezers for long-term storage of media?
1 답변-
You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.
도움이 되었습니까?
-
-
What tubing can be used with Stericup® and Steritop® vacuum filters?
What tubing can be used with Stericup® and Steritop® vacuum filters?
1 답변-
Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004
도움이 되었습니까?
-
-
What is the expiration date of Stericup® and Steritop® filters?
1 답변-
Typically 3 years from sterilization.
도움이 되었습니까?
-
-
What is the chemical compatibility of the various Stericup® and Steritop® filters?
What is the chemical compatibility of the various Stericup® and Steritop® filters?
1 답변-
Please refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
도움이 되었습니까?
-
-
What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?
1 답변-
All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
*Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.도움이 되었습니까?
-
-
Can we filter oil-type liquids with Stericup® filters?
Can we filter oil-type liquids with Stericup® filters?
1 답변-
Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
도움이 되었습니까?
-
-
What Bacterial Endotoxins Test is used?
1 답변-
The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.
도움이 되었습니까?
-
-
The User Guide says “Use only glass or plastic bottles designed for vacuum applications”. Can you specify which bottles are compatible?
1 답변-
Steritop® Quick Release bottle top units require a vacuum-rated receiver bottle with either a GL33 or GL45 mm closure thread as specified. Steritop® E bottle top units require a vacuum-rated receiver bottle with a GL45 mm closure thread. Bottles no larger than 2 L should be used.
Glass bottles, GL33:
• Wheaton media bottles (glass), 500 mL (Product Z364886)
• Wheaton media bottles (glass), 1 L (Product Z364894)
Glass bottles, GL45
• Corning® glass media storage bottle, 125 mL (Product CLS1399125)
• Corning® glass media storage bottle, 250 mL (Product CLS1399250)
• Corning® glass media storage bottle, 500 mL (Product CLS1399500)
• Corning® glass media storage bottle, 1 L (Product CLS13991L)
• Pyrex® round media storage bottle, 500 mL (Product CLS1395500)
• Pyrex® round media storage bottle, 1 L (Product CLS13951L)
• KIMBLE® KIMAX® Media bottle, 250 mL (Product DWK14395250)
• KIMBLE® KIMAX® Media bottle, 500 mL (Product DWK14395500)
• KIMBLE® KIMAX® Media bottle, 1 L (Product DWK143951000)
Plastic (pre-sterile) bottles, GL45:
• Stericup® Quick Release Receiver flask, 250 mL (Product S200B02RE)
• Stericup® Quick Release Receiver flask, 500 mL (Product S200B05RE)
• Stericup® Quick Release Receiver flask, 1000 mL (Product S200B10RE)도움이 되었습니까?
-
활성 필터
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.