RV1MAG-26K
MILLIPLEX® Rat Vascular Injury Magnetic Bead Panel 1 - Toxicity Multiplex Assay
The analytes available for this multiplex kit are: Caveolin-1, CINC-1/GRO/KC, CTGF (Connective Tissue Growth Factor), IL-6, MCP-1, PAI-1 (total), TIMP-1, TNFα, VEGF.
동의어(들):
Luminex® Rat Vascular Injury Panel, Millipore Rat Vascualr Injury Panel, Rat Vascular Injury Multiplex Assay
About This Item
추천 제품
Quality Level
종 반응성
rat
제조업체/상표
Milliplex®
assay range
accuracy: 97-108%
intra-assay cv: <10%
standard curve range: 0.1-100 ng/mL
(CINC-1/GRO/KC, IL-6, MCP-1, PAI-1 (total))
standard curve range: 0.1-15 ng/mL
(VEGF)
standard curve range: 0.1-20 ng/mL
(TNFα)
standard curve range: 0.2-150 ng/mL
(TIMP-1)
standard curve range: 0.3-200 ng/mL
(CTGF)
standard curve range: 1.4-1,000 ng/mL
(Caveolin-1)
inter-assay cv: <10%
(All other analytes)
inter-assay cv: <15%
(CINC-1/GRO/KC, PAI-1 (total), TIMP-1, TNFα)
inter-assay cv: <20%
(Caveolin-1)
기술
multiplexing: suitable
검출 방법
fluorometric (Luminex xMAP)
배송 상태
wet ice
일반 설명
The MILLIPLEX® Rat Vascular Injury Bead Panel contains all the components necessary to measure the following 9 biomarkers in any combination using Luminex® xMAP® technology: Caveolin-1, CINC-1/GRO/KC, CTGF (Connective Tissue Growth Factor), IL-6, MCP-1, PAI-1 (total), TIMP-1, TNFα, VEGF. The kit uses a 96-well format, contains a lyophilized standard cocktail, 2 quality controls and can measure up to 38 serum or plasma samples in duplicate.
Panel Type: Toxicity
특이성
애플리케이션
- Analytes: Caveolin-1, CINC-1/GRO/KC, CTGF (Connective Tissue Growth Factor), IL-6, MCP-1, PAI-1 (total), TIMP-1, TNF-α, VEGF
- Recommended Sample type: serum and plasma
- Recommended Sample dilution: 1:4 in kit Serum Matrix
- Assay Run Time: Overnight
- Research Category: Toxicity
특징 및 장점
포장
저장 및 안정성
기타 정보
법적 정보
면책조항
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
표적 기관
Respiratory Tract
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
관련 콘텐츠
Multiplex toxicity assays enable researchers to simultaneously measure multiple toxicity biomarkers of various organs to gain a better understanding of toxicity. Explore how MILLIPLEX® multiplex toxicity assays are advancing research on liver injury, kidney toxicity, genotoxicity, and more.
활성 필터
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.