콘텐츠로 건너뛰기
Merck
모든 사진(1)

문서

MAIPN4550

Millipore

Multiscreen® 96 well Plate, hydrophobic PVDF membrane

pore size 0.45 μm, non-sterile

동의어(들):

Hydrophobic 96-Well Plate, PVDF 96-Well Plate, PVDF Membrane Plate

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41104923
eCl@ss:
32039006
NACRES:
NB.22

material

PVDF membrane (hydrophobic)
acrylic
flat bottom wells

Quality Level

설명

Non-sterile, clear 96-well filter plate with 0.45 um pore size Hydrophobic PVDF membrane for Avidin-biotin Linkages, DNA-binding Proteins, Protein Binding & PAMPA. Comes in a pack of 50.

무균

non-sterile

제품 라인

MultiScreen®

특징

hydrophobic
lid

제조업체/상표

MultiScreen®

파라미터

50-250 μL sample volume (per well)

기술

parallel artificial membrane permeation assay (PAMPA): suitable

여과 면적

0.3 cm2

플레이트 크기

96 wells

웰 최대 용적

300 μL

작업 용적

50-250 μL

기질

Immobilon®-P

공극 크기

0.45 μm pore size

결합 유형

high binding surface

배송 상태

ambient

애플리케이션

MultiScreen®-IP Filter Plate, 0.45 μm, clear, non-sterile has been used:
  • as artificial membrane support and a receiver plate in parallel artificial membrane permeation assays (PAMPA) to determine the permeabilities of oximes
  • in enzyme-linked immunospot (ELISpot) assay
  • in keyhole limpet hemocyanin (KLH)-specific ELISPOT for the identification of antigen (Ag)-specific cells

법적 정보

Immobilon is a registered trademark of Merck KGaA, Darmstadt, Germany
MULTISCREEN is a registered trademark of Merck KGaA, Darmstadt, Germany

Not finding the right product?  

Try our 제품 선택기 도구.


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

A C Belkina et al.
Journal of dental research, 99(7), 855-862 (2020-03-19)
Periodontitis (PD) is a common source of uncontrolled inflammation in obesity-associated type 2 diabetes (T2D). PD apparently fuels the inflammation of T2D and associates with poor glycemic control and increased T2D morbidity. New therapeutics are critically needed to counter the
Claudia Giesecke et al.
Journal of immunology (Baltimore, Md. : 1950), 200(12), 3981-3992 (2018-05-08)
There are currently limited insights into the progression of human primary humoral immunity despite numerous studies in experimental models. In this study, we analyzed a primary and related secondary parenteral keyhole limpet hemocyanin (KLH) immunization in five human adults. The
Hee Chun Jeong et al.
Bioorganic & medicinal chemistry, 17(17), 6213-6217 (2009-08-12)
A series of fluorinated oxime compounds was designed and synthesized in order to probe the effect of fluorine substitution on reactivation of inhibited acetylcholinesterase (AChE) by organophosphorus agents. Permeability measurements, using the Parallel Artificial Membrane Permeation Assays (PAMPA) method, were

문서

This is a white paper on the Evaluation of the reproducibility of Parallel Artificial Membrane Permeation Assays (PAMPA) using MultiScreen® Filter Plates.

This is a protocol for a Membrane Integrity test for Lipid-PAMPA Artificial Membranes

Combining solubility & PAMPA assays streamlines drug permeability testing.

프로토콜

Assays that predict passive absorption of orally administered drugs have become increasingly important in the drug discovery process. As previously described by Faller and Kansy such assays provide rapid, low cost and automation friendly methods to measure a compound’s passive permeability.

Guidelines for various bioassays on the MultiScreen system, which makes it possible to carry out an assay from sample incubation to scintillation counting in a 96-well plate.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.