콘텐츠로 건너뛰기
Merck
모든 사진(3)

문서

LI0691BC

Millipore

TRANSIA® PLATE Listeria spp.

BioControl, ELISA test for detection of Listeria in food and environmental samples

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41116129
NACRES:
NA.85

Agency

AFNOR

제품 라인

TRANSIA®

유통기한

3‑24 mo.

포장

pkg of 96 tests

제조업체/상표

BioControl Systems LI0691

기술

ELISA: suitable

입력

food(s)

응용 분야

food and beverages
pathogen testing

저장 온도

2-8°C

적합성

Listeria spp.

일반 설명

TRANSIA® PLATE Listeria is a kit for detection of the Listeria genus(L. monocytogenes, L. ivanovii, L. innocua, L. seeligeri, L. welshimeri, L. grayi )in dairy products, meat products, seafood products, vegetables, and environmental samples.

애플리케이션

AFNOR Certification TRA 02/06 – 11/95

특징 및 장점

  • Detects all 6 species of Listeria providing a true indication of product and surface quality.
  • Positive and Negative controls supplied with the kit.

성분

  • 1 microplate with dividable microwell strips with 96 wells (12 microwell strips of 8 microwells).
  • Negative control: (bacterial antigens not belonging to the Listeria genus), ready-to-use, 10 mL.
  • Positive control: Listeria monocytogenes antigens, ready-to-use, 8 mL.
  • Conjugate (contains peroxidase conjugated anti-Listeria antibodies), ready-to-use, 16 mL.
  • Wash buffer, 20 X concentration, 60 mL.
  • Substrate (urea H2O2), ready-to-use, 57 mL.
  • Chromogen (TMB), ready-to-use, 57 mL.
  • Stop solution (H2SO4), ready-to-use, 57 mL.
  • 1 microplate cover.

원리

TRANSIA® PLATE Listeria is an ELISA test (Enzyme Linked Immuno Sorbent Assay) based on a two step sandwich-type reaction. The solid support of the reaction is a microtitration plate with dividable microwellstrips. Specific antibodies of flagellar antigens are grafted on the microtitration plate wells.

검사법

ELISA

법적 정보

TRANSIA is a registered trademark of Merck KGaA, Darmstadt, Germany

픽토그램

Skull and crossbonesHealth hazardCorrosion

신호어

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 1

표적 기관

Eyes,Central nervous system

Storage Class Code

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.