콘텐츠로 건너뛰기
Merck

KVEPG03TB3

Millipore

Millipore Express® SHR 0.1µm, Opticap® XL 3 Capsule

Fittings 1-1/2 in. TC- 1 in. HB, Gamma Compatible

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
23151806
가격 및 재고 정보를 현재 이용할 수 없음

제품명

Millipore Express® SHR, Opticap® XL Capsule, Opticap® XL 3, cartridge nominal length 3 in. (7.5 cm), filter diam. 10.7 cm (4.2 in.)

material

polyester support
polypropylene device
polypropylene housing
polypropylene vent cap
silicone seal

Quality Level

규정 준수

meets FDA 21 CFR 177-182 (all component materials)

무균

non-sterile

멸균 적합성

gamma compatible

제품 라인

Opticap® XL 3

특징

hydrophilic

제조업체/상표

Millipore Express®

파라미터

1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

기술

sterile filtration: suitable

너비

4.2 in.

카트리지 공칭 길이

3 in. (7.5 cm)

장치 길이

17.3 cm (6.8 in.)

장치 크기

3 in.

필터 직경

10.7 cm (4.2 in.)

필터 여과 영역

0.17 m2

불순물

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)

Matrix

Millipore Express® SHR

공극 크기

0.1 μm pore size

버블 포인트(bubble point)

≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water

피팅

(38 mm (1 ½ in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Device Configuration: Capsule

포장

Double Easy-Open bag

제조 메모

Sterilization Method:
Gamma Compatible to 45 kGy. May be autoclaved for 3 cycles of 60 min at 123 °C; not in-line steam sterilizable
This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

분석 메모

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.
TOC/Conductivity: After sterilization and a controlled water flush of 3.5 L, samples exhibited &#x3C 500 ppb TOC per USP &#x3C 643 &#x3C and &#x3C 1.3 μS/cm per USP &#x3C 645 &#x3C at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 1 L

기타 정보

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

법적 정보

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Emprove® 프로그램이란?

Emprove® 프로그램은 자사의 필터 그리고 일회용 구성품, 제약용 원료 물질 및 시작 물질의 종합적이고 빈틈없는 문건을 제공하는 체계입니다.

Material Qualification Dossier

무료 - 다운로드하려면 로그인하십시오

Material Qualification Dossier

무료 - 다운로드하려면 로그인하십시오

혜택 자세히 보기 Emprove®프로그램 구독권은 다음을 제공합니다
이러한 문서를 이용할 수 없는 이유는?
Emprove® 자료는 제약 생산자의 등록 과정 및 위험성 평가 활동을 지원하도록 의도된 정보 그리고 기밀 정보를 포함합니다. 열람하기 원하시면 문의 사항 하십시오.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

질문

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..