콘텐츠로 건너뛰기
Merck

KHVES3TTB1

Millipore

Millipore Express® SHR with prefilter 0.5/0.1µm, Opticap® XLT 30 Capsule

Fittings 1-1/2 in. TC- 1 in. HB, Sterile

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
23151806
가격 및 재고 정보를 현재 이용할 수 없음

제품명

Millipore Express® SHRP, Opticap® XLT Capsule, sterile, Opticap® XLT 30, cartridge nominal length 30 in. (75 cm), filter diam. 19.8 cm (7.8 in.)

material

polyester support
polypropylene device (gamma stable)
polypropylene housing
polypropylene vent cap (gamma stable)
polysulfone device
silicone seal

Quality Level

규정 준수

meets FDA 21 CFR 177-182 (all component materials)

무균

irradiated
sterile

제품 라인

Opticap® XLT 30

특징

hydrophilic

제조업체/상표

Millipore Express®

파라미터

≤91.2 mL/min air diffusion at 3.45 bar (50 psig) (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

기술

sterile filtration: suitable

카트리지 공칭 길이

30 in. (75 cm)

장치 길이

87.1 cm (34.3 in.)

장치 크기

30 in.

필터 직경

19.8 cm (7.8 in.)

필터 여과 영역

1.62 m2

불순물

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)

Matrix

Millipore Express® SHR (w/Prefilter)

pore size

0.5/0.1 μm pore size

버블 포인트(bubble point)

≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water

피팅

(38 mm (1 ½ in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Device Configuration: Capsule
T-line/Gauge Port: T-line

포장

Double Easy-Open bag

제조 메모

Sterilization Method:
3 autoclave cycles of 60 min at 123 °C; not in-line steam sterilizable
This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

분석 메모

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.
TOC/Conductivity: After sterilization and a controlled water flush of 60 L, samples exhibited &#x3C 500 ppb TOC per USP &#x3C 643 &#x3C and &#x3C 1.3 μS/cm per USP &#x3C 645 &#x3C at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 6 L

기타 정보

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

법적 정보

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Emprove® 프로그램이란?

Emprove® 프로그램은 자사의 필터 그리고 일회용 구성품, 제약용 원료 물질 및 시작 물질의 종합적이고 빈틈없는 문건을 제공하는 체계입니다.

Material Qualification Dossier

무료 - 다운로드하려면 로그인하십시오

Material Qualification Dossier

무료 - 다운로드하려면 로그인하십시오

Operational Excellence Dossier

구독하거나 수수료를 지급하시면 이용 가능

혜택 자세히 보기 Emprove®프로그램 구독권은 다음을 제공합니다
이러한 문서를 이용할 수 없는 이유는?
Emprove® 자료는 제약 생산자의 등록 과정 및 위험성 평가 활동을 지원하도록 의도된 정보 그리고 기밀 정보를 포함합니다. 열람하기 원하시면 문의 사항 하십시오.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

질문

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.