추천 제품
생물학적 소스
human
Quality Level
재조합
expressed in Chem-3 cells
포장
pkg of 2 mL
제조업체/상표
ChemiScreen
Chemicon®
농도
0.5 mg/mL
기술
ligand binding assay: suitable (GTPγS)
radioligand binding assay (RLBA): suitable
UniProt 수납 번호
배송 상태
dry ice
일반 설명
Chemicon′s H1 membrane preparations are crude membrane preparations made from our proprietary stable recombinant cell lines to ensure high-level of GPCR surface expression; thus, they are ideal HTS tools for screening of antagonists of H1 interactions and its ligands. The membrane preparations exhibit a Kd of 4.5 nM for [3H]-Pyrilamine. With 3 nM [3H]-Pyrilamine, 5 mg/well and 10 mg/well H1 Membrane Prep typically yield greater than 3 and 6-fold signal-to-background ratios, respectively.
애플리케이션
생화학적/생리학적 작용
품질
10 µg/well | |
---|---|
Signal:Background | 6.6 |
Specific Binding (cpm) | 925 |
SPECIFICATIONS: 1 unit = 10 µg for most lots. Specific activity (units/µg) may vary between lots.
Bmax: 8.3 pmol/mg
Kd: 4.5 nM
Note: Lot number MM1357015 contains 2 mL at 2 mg/mL, for which 1 unit = 20 µg
규격
Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, a GF/C 96-well filter plate is coated with 0.33% polyethyleneimine for 30 min, then washed with 50 mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.
Binding buffer: 50 mM Tris, pH 7.4, 10 mM MgCl2, 1 mM EDTA, filtered and stored at 4°C
Radioligand: [3H] Pyrilamine (Perkin Elmer#:NET594250UC )
Wash Buffer: 50 mM Tris, pH 7.4 filtered and stored at 4°C.
One package contains enough membranes for at least 200 assays (units), where an unit is the amount of membrane that will yield greater than 3-fold signal:background with 3H-labeled Pyrilamine at 3 nM
물리적 형태
저장 및 안정성
법적 정보
면책조항
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Storage Class Code
12 - Non Combustible Liquids
WGK
WGK 2
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
활성 필터
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.