추천 제품
material
polyethersulfone
polypropylene
polypropylene support
polysulfone
silicone seal
Quality Level
규정 준수
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
무균
non-sterile
멸균 적합성
autoclavable compatible
steam-in-place compatible
제품 라인
EMPROVE® Filter
Millipore Express®
특징
hydrophilic
제조업체/상표
Millipore Express®
파라미터
≤30 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
0.07 bar max. inlet pressure (1 psi) at 135 °C (Reverse)
0.35 bar max. inlet pressure (5 psi) at 135 °C (Forward)
1.7 bar max. inlet pressure (25 psi) at 80 °C (Forward)
1700 bar max. differential pressure (25 psi) at 80 °C (Forward)
2.07 bar max. inlet pressure (30 psi) at 25 °C (Reverse)
2100 mbar max. differential pressure (30 psi) at 25 °C (Reverse)
340 mbar max. differential pressure (5 psi) at 135 °C (Forward)
69 mbar max. differential pressure (1 psi) at 135 °C (Reverse)
6900 mbar max. differential pressure (100 psi) at 25 °C (Forward)
7 bar max. inlet pressure (100 psi) at 25 °C (Forward)
기술
sterile filtration: suitable
길이
10 in.
너비
2.7 in.
카트리지 공칭 길이
10 in. (25 cm)
직경
6.9 cm (2.7 in.)
여과 면적
0.54 m2
불순물
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
기질
Millipore Express® SHF
공극 크기
0.2 μm pore size
입력
sample type liquid
버블 포인트(bubble point)
≥4000 mbar (58 psig), air with water at 23 °C
카트리지 코드
Code 7
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
포장
기타 정보
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
- Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
제조 메모
25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
분석 메모
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 10 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
법적 정보
Not finding the right product?
Try our 제품 선택기 도구.
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.