추천 제품
Quality Level
일반 설명
The Magna ChIRP RNA Interactome Kit uses the ChIRP method (Chromatin Isolation by RNA Purification) to enable identification and analysis of regions of chromatin that interact with a particular chromatin-associated RNA. This novel anti-sense probe-based capture strategy uses cross-linked chromatin to allow unbiased discovery of RNA-associated DNA sequences and proteins. To perform ChIRP two pools consisting of mulitple biotinylated oligonucleotide probes complementary to the RNA of interest are used (see figure 1). These probe sets are combined with chromatin and hybridized to the chromatin-associated RNA. Complexes containing biotinylated-probes bound to the chromatin-associated RNA are then isolated using streptavidin magnetic beads. DNA or RNA can then be recovered and analyzed by quantitative PCR or next generation sequencing (ChIRP-seq). Alternatively, proteomic analysis of the recovered chromatin can be performed.
애플리케이션
The EZ-Magna ChIRP RNA Interactome Kit allows analysis, and mapping of regions of chromatin interacting with chromatin-associated RNAs. Based on the ChIRP method (chromatin isolation by RNA purification), this probe-based capture assay enables discovery of RNA-associated DNA sequences and proteins.
포장
Kit capacity: 12 Chromatin Isolation by RNA Purification Assays (includes negative control probes, even and odd positive control TERC lncRNA probes, and control PCR primer sets)
성분
10X Glycine ;Lysis Buffer;Hybridization Buffer (without 15% formamide) ;Wash Buffer;Proteinase K Buffer (for DNA);Proteinase K Buffer (for RNA);DNA Elution Buffer;0.5M EDTA;Streptavidin Magnetic Beads;RNase Inhibitor;Protease Inhibitor Cocktail III;Proteinase K Solution;DNase I RNase free;DNase I Reaction Buffer;RNase A (20 mg/mL);RNase H (10U/ μL);Magna ChIRP Negative Control Probe Set (LacZ) ;Magna ChIRP TERC lncRNA Probe Set (Even) ;Magna ChIRP TERC lncRNA Probe Set (Odd) ;RNA Positive Control Primers (TERC Gene);RNA Negative Control Primers (GAPDH Gene);Magna ChIRP Primers, WNT-1 precursor ;ChIP Primers, GAPDH coding D2
법적 정보
MAGNA CHIRP is a registered trademark of Merck KGaA, Darmstadt, Germany
면책조항
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Resp. Sens. 1
Storage Class Code
10 - Combustible liquids
WGK
WGK 3
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.