추천 제품
product name
Purospher® STAR NH2 (5 µm), L × I.D. 4 mm x 4 mm LiChroCART® Guard-cartridge
material
stainless steel column
Quality Level
Agency
suitable for USP L8
제품 라인
Purospher®
특징
endcapped: no
포장
10 pak of
라벨링 범위
3.5% Carbon loading
파라미터
250 bar pressure
60 °C max. temp.
기술
HPLC: suitable
LC/MS: suitable
mass spectrometry (MS): suitable (Low - Medium)
컬럼 길이 × I.D.
0.4 cm × 4 mm
표면적
330 m2/g
기질
fully porous particle
기질 활성군
NH2 bonding phase
입자 크기
5 μm
공극 크기
120 Å pore size
operating pH range
2-7.5
분리 기술
hydrophilic interaction (HILIC)
normal phase
reversed phase
저장 온도
no temp limit
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Purospher® STAR NH2, 5 µm HPLC columns are widely used for carbohydrate analysis, with a typical mobile phase consisting of acetonitrile and water. Purospher® STAR NH2, 5 µm LiChroCART® 4-4 is a guard cartridge which allows the integration into a manuCART™ cartridge column holder part number 1.51486.0001 for direct, dead volume free connection to an analytical LiChroCART® cartridge column with inner dimension of 2, 3, 4, or 4.6 mm I.D. and a column length of 75, 100, 125, 150 or 250 mm.For direct connection to a Hibar® RT columns the Precolumn holder for 4-4 LiChroCART® cartridges, part number 1.51487.0001 can be used.For connection to any other analytical HPLC column with capillary connection the Precolumn holder for 4-4 LiChroCART® cartridges, part number 1.16217.0001 is suitable.Learn more about Purospher® STAR HPLC and UHPLC ColumnsLearn more about the Supelco HPLC Column portfolio and Method development:Brochure: HPLC and UHPLC Column Selection GuideBrochure: A Practical Guide to HPLC - Method Development Guide
애플리케이션
Intended to be used in the separation of alcohols, carboxylic acids, fat soluble vitamins, nucleotides,steroids, sugars,sugar alcohols, sweeteners, and water soluble vitamins.
특징 및 장점
- Ultra-pure silica (99.999%)
- Low silanol activity
- Reproducible results from run-to-run and batch-to-batch
분석 메모
visual control (for delivery): passes test
Application test
- performance:
passes test
- pressure: passes test
Application test
- performance:
passes test
- pressure: passes test
법적 정보
Hibar is a registered trademark of Merck KGaA, Darmstadt, Germany
LICHROCART is a registered trademark of Merck KGaA, Darmstadt, Germany
MANUCART is a trademark of Merck KGaA, Darmstadt, Germany
Purospher is a registered trademark of Merck KGaA, Darmstadt, Germany
Storage Class Code
11 - Combustible Solids
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.