추천 제품
product name
Nitric acid 65%, Suprapur®
Grade
for inorganic trace analysis
Quality Level
Agency
suitable for EPA 200.7
suitable for EPA 200.8
vapor pressure
9.4 hPa ( 20 °C)
분석
65%
형태
liquid
pH
<1 (20 °C in H2O, strongly acid)
bp
121 °C/1013 hPa
mp
-32 °C
density
1.39 g/cm3 at 20 °C
저장 온도
2-30°C
SMILES string
O[N+]([O-])=O
InChI
1S/HNO3/c2-1(3)4/h(H,2,3,4)
InChI key
GRYLNZFGIOXLOG-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
관련 카테고리
결합
분석 메모
Chloride (Cl): ≤ 50 ppb
Phosphate (PO₄): ≤ 10 ppb
Sulphate (SO₄): ≤ 200 ppb
Ag (Silver): ≤ 0.5 ppb
Al (Aluminium): ≤ 10.0 ppb
As (Arsenic): ≤ 0.5 ppb
Au (Gold): ≤ 0.1 ppb
Ba (Barium): ≤ 0.5 ppb
Be (Beryllium): ≤ 0.5 ppb
Bi (Bismuth): ≤ 0.5 ppb
Ca (Calcium): ≤ 10.0 ppb
Cd (Cadmium): ≤ 0.5 ppb
Co (Cobalt): ≤ 0.5 ppb
Cr (Chromium): ≤ 1.0 ppb
Cu (Copper): ≤ 0.5 ppb
Fe (Iron): ≤ 2.0 ppb
Ga (Gallium): ≤ 0.1 ppb
Ge (Germanium): ≤ 0.1 ppb
Hg (Mercury): ≤ 1.0 ppb
In (Indium): ≤ 0.5 ppb
K (Potassium): ≤ 10.0 ppb
Li (Lithium): ≤ 0.5 ppb
Mg (Magnesium): ≤ 10.0 ppb
Mn (Manganese): ≤ 0.5 ppb
Mo (Molybdenum): ≤ 0.5 ppb
Na (Sodium): ≤ 10.0 ppb
Ni (Nickel): ≤ 5.0 ppb
Pb (Lead): ≤ 2.0 ppb
Pt (Platinum): ≤ 0.5 ppb
Sb (Antimony): ≤ 0.5 ppb
Sn (Tin): ≤ 0.5 ppb
Sr (Strontium): ≤ 0.5 ppb
Ti (Titanium): ≤ 1.0 ppb
Tl (Thallium): ≤ 0.5 ppb
V (Vanadium): ≤ 0.5 ppb
Zn (Zinc): ≤ 2.0 ppb
Zr (Zirconium): ≤ 1.0 ppb
Residue on ignition (as sulphate): ≤ 2 ppm
Actual analysis values are subject to unavoidable systematic variations in this concentration range
The actual values are subject to unavoidable systematic
variations in this concentration range.
법적 정보
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Inhalation - Eye Dam. 1 - Met. Corr. 1 - Ox. Liq. 3 - Skin Corr. 1A
보충제 위험성
Storage Class Code
5.1B - Oxidizing hazardous materials
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
문서
Acid and base chart lists the strength of acids and bases (strongest to weakest) in order. Simple to use laboratory reference chart for scientists, researchers and lab technicians.
Control elemental impurities in drug products with analytical methods and materials to ensure patient safety.
A 4-step comprehensive ICP-MS workflow including sample homogenization, with standard addition calibration method, to determine heavy metals in Cannabis sativa.
관련 콘텐츠
This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.