추천 제품
종 반응성
canine, feline, porcine, rat, nonhuman primates
제조업체/상표
SMC®
assay range
sensitivity: 0.062 pg/mL
(lower limit of quantification)
inter-assay cv: <13%
intra-assay cv: <9%
기술
ELISA: suitable
single molecule counting: suitable
관련 질환(들)
autoimmune diseases
저장 온도
2-8°C
일반 설명
The SMC® Human IFN-α2 High Sensitivity Immunoassay Kit contains all reagents required to perform the assay. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format.
Assay protocols are similar to existing sandwich ELISA methods with two key differences:
1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification.
2) The Erenna and SMCxPRO® immunoassay systems detect analytes using Single Molecule Counting (SMC®) technology.
특이성
This assay was tested for cross reactivity with rhIFN-β, rhIFN-γ, rhIFN-λ1 (IL-29), rhIFN-λ2 (IL28A), rhIFN-λ3 (IL-28B), rhIFN-ω, IFN-α2a, IFN-α2b and IFN-α.
- There is no cross-reactivity detected with rhIFN-ß, rhIFN-γ, rhIFN-λ1 (IL-29), rhIFN-λ2 (IL-28A),rhIFN-λ3 (IL-28B), and rhIFN-ω.
- There is 100% cross-reactivity with IFN-α2a.
- There is 49% cross-reactivity with IFN-α2b.
- There is 3% cross-reactivity with IFN-α.
Accuracy:
- Minimum of 5 serum samples spiked with average recovery of 102% with a range of 92-111%
- Minimum of 5 plasma samples spiked with average recovery of 96% with a range of 89-107%
애플리케이션
- Inflammation & Immunology
Research Sub-Category:
- Inflammatory Disease
- Immune Response
- Autoimmune disease
The sensitivity of the Single Molecule Counting (SMC®) technology gives the SMC® Human IFN-a2 High Sensitivity Immunoassay Kit unparalleled performance in the quantification of IFN-a2 in human serum and plasma.
특징 및 장점
- Improved options for sample prep and incubation
- Lyophilization of the standard provides the kit at one storage condition
- Removal of a plate transfer step
- Increased reagent volumes to accommodate automation
- Validated to run on both SMCxPRO® and Erenna
성분
- Assay Buffer
- IFN-a2 Coated Beads
- Standard Diluent
- IFN-a2 Detection Antibody
- IFN-a2 Standard
- 10X Wash Buffer
- Buffer D
- Elution Buffer B
분석 메모
법적 정보
면책조항
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
관련 콘텐츠
단일분자계수 (Single Molecule Counting, SMC®) 기술을 사용한 초고감도 분석 기술 개요를 살펴보십시오. 이에는 해당 기술의 워크플로, 바이오마커 감지 플랫폼, 연구 영역, 고감도 SMC 검사의 장점 등이 포함되어 있습니다.
Explore ultrasensitive immunoassay technology with SMC® technology, including its biomarker detection platform, advantages of high sensitivity assays, and more.
SMC® 기술을 활용하여 Th1/Th2 및 Th17 세포와 같이 낮은 수준의 사이토카인을 정확하게 특성화함으로써 고감도 면역학 분석의 힘을 통해 면역학 연구를 향상시키는 방법을 알아보세요.
Use the power of high sensitivity immunology assays with SMC® technology to precisely characterize low-abundant cytokines like those from Th1/Th2 and Th17 cells.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.