콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

W382501

Sigma-Aldrich

Diethyl sulfide

98%, FG

동의어(들):

1,1′-Thiobisethane, Ethyl sulfide, NSC 75157

로그인조직 및 계약 가격 보기

크기 선택

W382501-SAMPLE
₩81,200
100 G
₩162,502
1 KG
₩551,754

₩81,200


구입 가능 여부는 고객센터에 문의하십시오.

벌크 견적 요청추가 정보 요청

크기 선택

보기 변경
W382501-SAMPLE
₩81,200
100 G
₩162,502
1 KG
₩551,754

About This Item

Linear Formula:
(C2H5)2S
CAS Number:
Molecular Weight:
90.19
FEMA Number:
3825
Beilstein:
1696909
EC Number:
MDL number:
UNSPSC 코드:
12164502
PubChem Substance ID:
플래비스(Flavis) 번호:
12.113
NACRES:
NA.21

₩81,200


구입 가능 여부는 고객센터에 문의하십시오.

벌크 견적 요청추가 정보 요청

생물학적 소스

synthetic

Grade

FG
Halal

규정 준수

EU Regulation 1334/2008 & 872/2012
FDA 21 CFR 110

vapor pressure

105 mmHg ( 37.7 °C)

분석

98%

refractive index

n20/D 1.442 (lit.)

bp

90-92 °C (lit.)

mp

−100 °C (lit.)

density

0.837 g/mL at 25 °C (lit.)

응용 분야

flavors and fragrances

문건

see Safety & Documentation for available documents

식품 알레르기항원

no known allergens

감각 수용성의

sulfurous

SMILES string

CCSCC

InChI

1S/C4H10S/c1-3-5-4-2/h3-4H2,1-2H3

InChI key

LJSQFQKUNVCTIA-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

관련 카테고리

픽토그램

FlameExclamation mark

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Eye Irrit. 2 - Flam. Liq. 2 - Skin Irrit. 2

Storage Class Code

3 - Flammable liquids

WGK

WGK 3

Flash Point (°F)

15.8 °F - closed cup

Flash Point (°C)

-9 °C - closed cup

개인 보호 장비

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

Beer Singh et al.
Journal of hazardous materials, 139(1), 38-43 (2006-08-26)
Breakthrough behavior of diethyl sulphide vapors on carbon systems such as active carbon, NaOH/CrO3/C, NaOH/CrO3/EDA/C and RuCl3/C has been studied by using modified Wheeler equation and the same was used to calculate the pseudo-first-order rate constant (kv) and kinetic saturation
R Singh et al.
Chemical research in toxicology, 10(1), 70-77 (1997-01-01)
Postlabeling can be one of the most sensitive methods for the measurement of DNA adducts. However, for the determination of alkylated adducts, essential requirements are standards which must be fully chemically characterized. In order to develop a postlabeling assay for
Taylor C Hayward et al.
Journal of chromatography. A, 1105(1-2), 66-70 (2005-09-30)
A recently reported micro-flame photometric detector (microFPD) has been examined in greater detail for its sulfur response characteristics. While supporting an "upside down" flame on a stainless steel capillary burner (delivering oxygen) in a counter flowing stream of premixed hydrogen
V Vodyanoy et al.
Neuroscience letters, 73(3), 253-258 (1987-01-27)
The steady-state conductance of planar bimolecular lipid membranes (BLMs) modified with rat olfactory epithelial homogenate (ROH) becomes sensitive to very low concentrations of odorant in the presence of adenosine triphosphate (ATP) and guanosine triphosphate (GTP). The chemosensitivity is not observed
Femtochemistry uncovers the nature of electron transfer reactions.
A W Castleman et al.
Proceedings of the National Academy of Sciences of the United States of America, 96(8), 4219-4220 (1999-04-14)

질문

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.