Grade
NMR reference standard
Quality Level
형태
solution
구성
1,2-dichloro-1,1-difluoroethane, 1%
TMS, 6%
농도
10% in acetone-d6 (99.9 atom % D)
기술
NMR: suitable
NMR 튜브 크기
5 mm × 8 in.
SMILES string
FC(Cl)(Cl)Cl
InChI
1S/CCl3F/c2-1(3,4)5
InChI key
CYRMSUTZVYGINF-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
관련 카테고리
수량
5 mm O.D. tube contains 0.700 mL.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Flam. Liq. 2 - Ozone 1 - STOT SE 3
표적 기관
Central nervous system
보충제 위험성
Storage Class Code
3 - Flammable liquids
WGK
WGK 3
Flash Point (°F)
32.0 °F - closed cup
Flash Point (°C)
0 °C - closed cup
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
Environmental science & technology, 41(4), 1145-1151 (2007-06-28)
HFC-365mfc (1,1,1,3,3-pentafluorobutane) is an industrial chemical used for polyurethane foam blowing. From early 2003, HFC-365mfc has been commercially produced as a substitute for HCFC-141b, whose use in Europe has been banned since January 2004. We describe the first detection of
Toxicological sciences : an official journal of the Society of Toxicology, 60(1), 20-27 (2001-02-27)
Human exposure guidelines for halogenated hydrocarbons (halons) and halon replacement chemicals have been established using dose-response data obtained from canine cardiac sensitization studies. In order to provide a tool for decision makers and regulators tasked with setting guidelines for egress
Rapid communications in mass spectrometry : RCM, 18(20), 2383-2387 (2004-09-24)
Nonresonant laser-induced multiphoton dissociation/ionization studies have been conducted for trichloromethane (CHCl3) and trichlorofluoromethane (CFCl3) at 355 nm, using time-of-flight mass spectrometry (TOFMS). The molecular ion signal was found to be missing for both these compounds, and very similar fragmentation patterns
Analytical biochemistry, 171(1), 150-157 (1988-05-15)
A one-vial procedure has been developed to quantify free fatty acids in human blood serum and rat heart tissue. To allow routine analysis the system has been constructed to allow simultaneous processing of nine samples (Praechromat). The free fatty acids
Journal of forensic sciences, 39(3), 871-876 (1994-05-01)
A case of lethal poisoning due to trichlorofluoromethane (FC11) inhalation is described. The fluorocarbon was determined in biological tissues by headspace gas chromatography-mass spectrometry. FC11 was detected in all the examined tissues, with decreasing levels in heart, lung, brain, liver