콘텐츠로 건너뛰기
Merck
모든 사진(2)

문서

704369

Sigma-Aldrich

Poly(ethylene glycol) dithiol

average Mn 1, 500, thiol

동의어(들):

Polyethylene glycol, PEG dithiol

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
HSCH2CH2(OCH2CH2)nSH
UNSPSC 코드:
12162002
NACRES:
NA.23

product name

Poly(ethylene glycol) dithiol, average Mn 1,500

형태

solid

분자량

Mn 1200-1800
average Mn 1,500

반응 적합성

reagent type: cross-linking reagent
reactivity: thiol reactive

mp

47-50 °C

Ω-끝

thiol

α-끝

thiol

폴리머 구조

shape: linear
functionality: homobifunctional

저장 온도

−20°C

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

  • Photocurable Bioink for the Inkjet 3D Pharming of Hydrophilic Drugs.: This research discusses the development of a photocurable bioink using poly(ethylene glycol) dithiol for the inkjet 3D printing of hydrophilic drugs. The study highlights the biocompatibility and potential applications in drug delivery systems (Acosta-Vélez et al., 2017).
  • Enhanced mechanical properties of photo-clickable thiol-ene PEG hydrogels through repeated photopolymerization of in-swollen macromer.: This study examines the use of poly(ethylene glycol) dithiol in creating thiol-ene hydrogels with enhanced mechanical properties. The repeated photopolymerization technique improves the hydrogel′s stability and applicability in medical devices and tissue engineering (Fiedler et al., 2016).
  • Degradative properties and cytocompatibility of a mixed-mode hydrogel containing oligo[poly(ethylene glycol)fumarate] and poly(ethylene glycol)dithiol.: The paper explores the degradative behavior and cytocompatibility of hydrogels composed of oligo[poly(ethylene glycol)fumarate] and poly(ethylene glycol)dithiol. The findings indicate favorable biocompatibility and potential for biomedical applications such as drug delivery and tissue engineering (Brink et al., 2009).

Storage Class Code

11 - Combustible Solids

WGK

nwg

Flash Point (°F)

>230.0 °F

Flash Point (°C)

> 110 °C

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Kelly C Santos Roballo et al.
Biomaterials, 209, 1-9 (2019-04-26)
Segmental injuries to peripheral nerves (PNs) too often result in lifelong disability or pain syndromes due to a lack of restorative treatment options. For injuries beyond a critical size, a bridging device must be inserted to direct regeneration. PN allografts

문서

Highlighting new synthetic modifications of PEG to improve the mechanical properties and degradation of resulting hydrogels in tissue engineering applications.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.