Journal of chromatography. A, 1216(35), 6326-6334 (2009-08-01)
A combination of fast GC with narrow-bore column and bench top quadrupole mass spectrometer (MS) detector in negative chemical ionization (NCI) mode (with methane as reagent gas) is set up and utilized for the ultratrace analysis of 25 selected pesticides.
Iprodione (IPRO) is a dichlorophenyl dicarboximide fungicide similar to procymidone and vinclozolin. All three of these fungicides induce Leydig cell tumors in the rat testis in long-term studies and an endocrine mode of action has been hypothesized to mediate this
The influence of humic aggregates in water solution upon the chemical stability of Iprodione has been investigated under basic conditions. Taking into account that an important part of soils are colloids, the possibility of its presence implies that soil composition
Journal of chromatography. A, 1218(52), 9375-9383 (2011-11-29)
A new type of low thermal mass (LTM) fast gas chromatograph (GC) was designed and operated in combination with gas chromatography mass spectrometry (GC-MS) with supersonic molecular beams (SMB), including GC-MS-MS with SMB, thereby providing a novel combination with unique
Journal of agricultural and food chemistry, 56(2), 502-506 (2007-12-21)
Both primary and secondary alcohols degrade iprodione, 3-(3,5-dichlorophenyl)-N-(1-methylethyl)-2,4-dioxo-1-imidazolidine carboxamide. Steric hindrance has been found to have an inverse effect on the rate of its decomposition, and a fully substituted alcohol, such as tert-butanol, does not degrade iprodione due to extreme