Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
추천 제품
양식
powder
Quality Level
라벨링 범위
~1 mmol/g NH2 loading
~9% functionalized
표면적
550 m2/g
Matrix
irregular silica particle platform
기질 활성군
NH2 phase
입자 크기
40-63 μm
공극 크기
60 Å pore size
SMILES string
O[SiH3].CCCN
InChI key
ZPPBNRTUMSCLLZ-UHFFFAOYSA-N
일반 설명
애플리케이션
- For the separation of polychlorinated biphenyls (PCBs) from lipids by combined supercritical fluid extraction and separation.[2]
- Preparation of the tin complex immobilized on silica gel, a novel, green, highly efficient and heterogeneous reusable catalyst.[3]
- Preparation of silica gel bearing isonicotinamide groups.[4]
- Synthesis of a novel catalytic system including Pd(OAc)2 attached to a bis(oxazoline) ligand that is covalently bonded to 3-mercaptopropyl-functionalized silica gel.[5]
- Useful as a heterogeneous, reusable catalyst for the Knoevenagel condensation.
- For low- and medium-pressure reversed-phase liquid chromatography.
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
가장 최신 버전 중 하나를 선택하세요:
시험 성적서(COA)
문서
Functionalized silica gel is used in size-exclusion chromatography of cationic polymers and in the separation of sugars, steroids, cholesterol, and triglycerides.
Knoevenagel Condensation is an organic reaction named after Emil Knoevenagel. It is a classic C-C bond formation reaction and a modification of the Aldol Condensation.
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 답변-
도움이 되었습니까?
-
-
How can I determine the shelf life / expiration / retest date of this product?
1 답변-
If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf도움이 되었습니까?
-
활성 필터
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.