콘텐츠로 건너뛰기
Merck
모든 사진(4)

주요 문서

237965

Sigma-Aldrich

Lithium fluoride

greener alternative

powder, -300 mesh

동의어(들):

Fluorolithium

로그인조직 및 계약 가격 보기

크기 선택

100 G
₩126,571
1 KG
₩446,803

₩126,571


예상 입고일2025년 4월 21일세부사항


벌크 견적 요청

크기 선택

보기 변경
100 G
₩126,571
1 KG
₩446,803

About This Item

Linear Formula:
LiF
CAS Number:
Molecular Weight:
25.94
EC Number:
MDL number:
UNSPSC 코드:
12352302
PubChem Substance ID:
NACRES:
NA.23

₩126,571


예상 입고일2025년 4월 21일세부사항


벌크 견적 요청

양식

powder

Quality Level

환경친화적 대안 제품 특성

Design for Energy Efficiency
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

입자 크기

-300 mesh

mp

845 °C (lit.)

density

2.64 g/mL at 25 °C (lit.)

환경친화적 대안 카테고리

SMILES string

[Li+].[F-]

InChI

1S/FH.Li/h1H;/q;+1/p-1

InChI key

PQXKHYXIUOZZFA-UHFFFAOYSA-M

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Lithium fluoride (LiF) is a highly versatile compound with a wide range of applications in research and development. Its unique physical and chemical properties make it suitable for use in optical components, battery technology, nuclear applications, ceramics, glasses, optoelectronics, metallurgy, thermoluminescent dosimeters, catalysis, environmental research, and biomedical applications.

We are committed to bringing you Greener Alternative Products, which adhere to one or more of The 12 Principles of Greener Chemistry. This product has been enhanced for energy efficiency. Click here for more information.

애플리케이션

Lithium Fluoride (LiF) can be used as an additive in electrolytes for lithium-ion batteries to enhance thermal stability and overall battery performance. Applied as a thin film on electrodes to improve their stability and lifespan by preventing degradation during cycling. LiF is a crucial component of the anode interface film due to its high-modulus shell, which can prevent LixSi pulverization, and its high chemical stability, which effectively suppresses side reactions at the interface. LiF is used in nuclear reactors and radiation detectors due to its low neutron cross-section and ability to capture neutrons, making it suitable for neutron shielding and detection.[1]

Lithium fluoride (LiF) can be used as a sintering aid that facilitates the etching of spinel particles for the degradation of magnesium aluminum spinel.[2] It can be used in the preparation of carbon-iron LiF nanocomposite based electrode materials for lithium-ion batteries.[3] It can also form thin interlayers on the counter electrode to enhance the fill factor and stabilize the high open-circuit voltages for polymer solar cells.[4]

픽토그램

Exclamation mark

신호어

Warning

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 4 Oral - Eye Irrit. 2

보충제 위험성

Storage Class Code

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

WGK

WGK 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Faceshields, Gloves, type P2 (EN 143) respirator cartridges


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

A ferrocene-based carbon-iron lithium fluoride nanocomposite as a stable electrode material in lithium batteries
Prakash R, et al.
Journal of Materials Chemistry, 20(10), 1871-1876 (2010)
Degradation of magnesium aluminum spinel by lithium fluoride sintering aid
Villalobos GR, et al.
Journal of the American Ceramic Society. American Ceramic Society, 88(5), 1321-1322 (2005)
Effect of LiFmetal electrodes on the performance of plastic solar cells
Brabec CJ, et al.
Applied Physics Letters, 80(7), 1288-1290 (2002)
Fluorescent detection of single tracks of alpha particles using lithium fluoride crystals
Bilski P and Marczewska B
Nuclear Instruments & Methods in Physics Research. Section B, Beam Interactions With Materials and Atoms, 392, 41-45 (2017)
Asa Carlsson Tedgren et al.
Medical physics, 38(10), 5539-5550 (2011-10-14)
High energy photon beams are used in calibrating dosimeters for use in brachytherapy since absorbed dose to water can be determined accurately and with traceability to primary standards in such beams, using calibrated ion chambers and standard dosimetry protocols. For

문서

Professor Gogotsi and Dr. Shuck introduce MXenes: a promising family of two-dimensional materials with a unique combination of high conductivity, hydrophilicity, and extensive tunability.

Solid-state lithium fast-ion conductors are crucial for safer, high-energy-density all-solid-state batteries, addressing conventional battery limitations.

Lithium-ion batteries' characteristics make them popular for electricity storage due to portability, rechargeability, and low cost.

질문

1–3 / 3 질문  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 답변
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      도움이 되었습니까?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 답변
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      도움이 되었습니까?

  3. What is the purity?

    1 답변
    1. This product is not tested for purity. The testing includes the appearance, particle size, and identity confirmation by X-Ray Diffraction. Please see the link below to review a sample Certificate of Analysis: https://www.sigmaaldrich.com/certificates/sapfs/PROD/sap/certificate_pdfs/COFA/Q14/237965-100G0000226203.pdf

      A highly purified version of the compound is available as product 449903. This material has a minimum purity specification of 99.99%. Please see the link below to review this product option:
      https://www.sigmaaldrich.com/product/aldrich/449903

      도움이 되었습니까?

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.