추천 제품
분석
99%
형태
liquid
불순물
1% methyl benzoate
refractive index
n20/D 1.532 (lit.)
bp
103-105 °C/14 mmHg (lit.)
density
1.101 g/mL at 25 °C (lit.)
SMILES string
CC(=O)C(=O)c1ccccc1
InChI
1S/C9H8O2/c1-7(10)9(11)8-5-3-2-4-6-8/h2-6H,1H3
InChI key
BVQVLAIMHVDZEL-UHFFFAOYSA-N
유전자 정보
human ... ACHE(43) , BCHE(590) , CES1(1066)
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
The enantioselective hydrogenation of 1-phenyl-1,2-propanedione over Pt colloids was studied.
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Oral - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
10 - Combustible liquids
WGK
WGK 3
Flash Point (°F)
183.2 °F - closed cup
Flash Point (°C)
84 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Dental materials : official publication of the Academy of Dental Materials, 22(6), 576-584 (2005-11-18)
To evaluate the efficiency of the photopolymerization of dental resins it is necessary to know to what extent the light emitted by the light curing units is absorbed by the photoinitiators. On the other hand, the efficiency of the absorbed
The Journal of organic chemistry, 73(17), 6559-6569 (2008-08-08)
Structures and conformational behavior of several cinchona alkaloid O-ethers in the solid state (X-ray), in solution (NMR and DFT), and in the gas phase (DFT) were investigated. In the crystal, O-phenylcinchonidine adopts the Open(3) conformation similar to cinchonidine, whereas the
Dental materials : official publication of the Academy of Dental Materials, 24(9), 1169-1177 (2008-03-08)
To evaluate the degree of conversion (DC), maximum rate of polymerization (Rpmax), Knoop hardness (KHN) and yellowing (b-value) of resin composites formulated with phenylpropanedione (PPD), camphorquinone (CQ), or CQ/PPD at different concentrations. The hypotheses tested were (i) PPD or CQ/PPD
Dental materials : official publication of the Academy of Dental Materials, 25(5), 566-572 (2008-12-30)
Stress development during the polymerization process continues to be a major factor that limits predictability and longevity of resin composite restorations. This study evaluated the effect of the photoinitiator type on the maximum rate of polymerization (R(p)(max)), stress development (final
Journal of dentistry, 39(6), 438-447 (2011-04-23)
The aim of this study was to evaluate the degree of conversion (DC), rate of polymerization (R(p)(max)), Knoop hardness (KHN) and bond strength between tooth/restoration of composite resins containing different photo-initiators photo-activated by different light-curing units (LCUs). A mixture of
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.