추천 제품
분석
≥99%
refractive index
n20/D 1.488 (lit.)
bp
247 °C (lit.)
mp
10 °C (lit.)
density
0.922 g/mL at 25 °C (lit.)
SMILES string
CC1(C)CC(N)CC(C)(CN)C1
InChI
1S/C10H22N2/c1-9(2)4-8(12)5-10(3,6-9)7-11/h8H,4-7,11-12H2,1-3H3
InChI key
RNLHGQLZWXBQNY-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
5-Amino-1,3,3-trimethylcyclohexanemethylamine, mixture of cis and trans (IPD), is an cyclo-aliphatic diamine that is mainly used as an epoxy curing agent.
애플리케이션
IPD is widely used as a hardener to cure a variety of epoxy based resins, such as diglycidyl ether bisphenol A (DGEBA), and diglycidyl ether 1,4-butanediol (DGEBU)..
애플리케이션
제품 번호
설명
가격
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Oral - Eye Dam. 1 - Skin Corr. 1B - Skin Sens. 1A
Storage Class Code
8A - Combustible corrosive hazardous materials
WGK
WGK 2
Flash Point (°F)
230.0 °F - closed cup
Flash Point (°C)
110 °C - closed cup
개인 보호 장비
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
PloS one, 9(12), e114149-e114149 (2014-12-03)
Tissue clearing allows microscopy of large specimens as whole mouse brains or embryos. However, lipophilic tissue clearing agents as dibenzyl ether limit storage time of GFP-expressing samples to several days and do not prevent them from photobleaching during microscopy. To
Divanillin-Based Epoxy Precursors as DGEBA Substitutes for Biobased Epoxy Thermosets
ACS sustainable chemistry & engineering, 6(8), 11008-11017 (2018)
High enthalpy storage thermoset network with giant stress and energy output in rubbery state
Nature Communications, 9(1), 642-642 (2018)
Journal of the American Academy of Dermatology, 25(2 Pt 2), 386-388 (1991-08-01)
A case of erythema multiforme associated with an allergic contact dermatitis in response to an epoxy-based compound is presented. Patch tests revealed a positive reaction to both the epoxy resin and the hardener. Chemicals applied directly to the skin should
The American review of respiratory disease, 145(5), 1217-1218 (1992-05-01)
An otherwise healthy 44-yr-old man experienced a serious attack of bronchial obstruction after working with resins and hardeners, releasing fumes of a mixture of an alipathic and a cycloaliphatic diamine hardener. Eight hours after deliberate challenge with the hardener a
Chromatograms
suitable for GCsuitable for GCsuitable for GC자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.