추천 제품
분석
97%
autoignition temp.
428 °F
refractive index
n20/D 1.394 (lit.)
bp
102-103 °C (lit.)
mp
−92 °C (lit.)
density
0.81 g/mL at 25 °C (lit.)
SMILES string
[H]C(=O)CCCC
InChI
1S/C5H10O/c1-2-3-4-5-6/h5H,2-4H2,1H3
InChI key
HGBOYTHUEUWSSQ-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Valeraldehyde also known as pentanal, serves as a precursor or intermediate to build more complex organic molecules.
애플리케이션
Valeraldehyde has been used to study its time-weighted average sampling using solid-phase microextraction (SPME) device.
Valeraldehyde is used as a gaseous standard in the study of the sorptive loss pattern for volatile compounds.
Valeraldehyde is used in flavoring compounds and as a rubber accelerator.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Inhalation - Eye Irrit. 2 - Flam. Liq. 2 - Skin Sens. 1 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
3 - Flammable liquids
WGK
WGK 1
Flash Point (°F)
44.6 °F
Flash Point (°C)
7 °C
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Journal of separation science, 35(21), 2914-2921 (2012-10-16)
In this study, the sorptive loss patterns for volatile organic compounds were evaluated by gaseous standards containing 13 compounds (benzene, toluene, styrene, p-xylene, methyl ethyl ketone, methyl isobutyl ketone, isobutyl alcohol, butyl acetate, acetaldehyde, propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde). The
Aldol condensation of cyclopentanone with valeraldehyde over metal oxides
Catalysis Letters, 149, 1383-1395 (2019)
Plant & cell physiology, 44(5), 481-490 (2003-05-30)
Induction of pumpkin (Cucurbita maxima Duch.) glutathione S-transferase (GST, EC 2.5.1.18) by aldehydes and related compounds was examined. All of the tested compounds induced pumpkin GST to different degrees, and it was found that (1) aldehydes induce GST directly and
Journal of chromatography. A, 954(1-2), 191-198 (2002-06-13)
A solid-phase microextraction (SPME) device was used as a time-weighted average sampler for n-valeraldehyde. The SPME device was first modified to improve the wearer's acceptance as a passive sampler. Then a poly(dimethylsiloxane)-divinylbenzene fiber was used and O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) was
Journal of food science, 74(9), S390-S398 (2010-05-25)
Milk packaged in glass bottles overwrapped with iridescent films (treatments blocked either a single visible riboflavin [Rb] excitation wavelength or all visible Rb excitation wavelengths; all treatments blocked UV Rb excitation wavelengths) was exposed to fluorescent lighting at 4 degrees
프로토콜
-Tolualdehyde; Valeraldehyde; Isovaleraldehyde
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.