コンテンツへスキップ
Merck
  • Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis.

Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis.

Acta orthopaedica (2014-06-17)
Klas Gustafson, Stig S Jakobsen, Nina D Lorenzen, Jacob P Thyssen, Jeanne D Johansen, Charlotte M Bonefeld, Maiken Stilling, Thomas Baad-Hansen, Kjeld Søballe
要旨

Metal-on-metal (MOM) total hip arthroplasties were reintroduced because of the problems with osteolysis and aseptic loosening related to polyethylene wear of early metal-on-polyethylene (MOP) arthroplasties. The volumetric wear rate has been greatly reduced with MOM arthroplasties; however, because of nano-size wear particles, the absolute number has been greatly increased. Thus, a source of metal ion exposure with the potential to sensitize patients is present. We hypothesized that higher amounts of wear particles result in increased release of metal ions and ultimately lead to an increased incidence of metal allergy. 52 hips in 52 patients (median age 60 (51-64) years, 30 women) were randomized to either a MOM hip resurfacing system (ReCap) or a standard MOP total hip arthoplasty (Mallory Head/Exeter). Spot urine samples were collected preoperatively, postoperatively, after 3 months, and after 1, 2, and 5 years and tested with inductively coupled plasma-sector field mass spectrometry. After 5 years, hypersensitivity to metals was evaluated by patch testing and lymphocyte transformation assay. In addition, the patients answered a questionnaire about hypersensitivity. A statistically significant 10- to 20-fold increase in urinary levels of cobalt and chromium was observed throughout the entire follow-up in the MOM group. The prevalence of metal allergy was similar between groups. While we observed significantly increased levels of metal ions in the urine during the entire follow-up period, no difference in prevalence of metal allergy was observed in the MOM group. However, the effect of long-term metal exposure remains uncertain.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
チミジン, powder, BioReagent, suitable for cell culture
Sigma-Aldrich
チミジン, ≥99%
Sigma-Aldrich
ポリエチレン, Ultra-high molecular weight, surface-modified, powder, 34-50 μm particle size
Sigma-Aldrich
ポリエチレン, average Mw ~4,000 by GPC, average Mn ~1,700 by GPC
Sigma-Aldrich
ポリエチレン, low density, melt index 25 g/10 min (190°C/2.16kg)
Sigma-Aldrich
チタン, foil, thickness 0.127 mm, 99.7% trace metals basis
Sigma-Aldrich
クロム, powder, ≥99% trace metals basis, <45 μm
Sigma-Aldrich
チタン, powder, <45 μm avg. part. size, 99.98% trace metals basis
Sigma-Aldrich
コバルト, powder, 2 μm particle size, 99.8% trace metals basis
Sigma-Aldrich
ポリエチレン, Ultra-high molecular weight, average Mw 3,000,000-6,000,000
Sigma-Aldrich
チタン, foil, thickness 0.25 mm, 99.7% trace metals basis
Sigma-Aldrich
コバルト, powder, <150 μm, ≥99.9% trace metals basis
Sigma-Aldrich
ポリエチレン, Medium density
Sigma-Aldrich
ポリエチレン, High density, melt index 12 g/10 min (190 °C/2.16kg)
Sigma-Aldrich
ポリエチレン, Linear low density, melt index 1.0 g/10 min (190°C/2.16kg)
Sigma-Aldrich
チタン, powder, −100 mesh, 99.7% trace metals basis
Sigma-Aldrich
ポリエチレン, Ultra-high molecular weight, surface-modified, powder, 125 μm avg. part. size
Sigma-Aldrich
ポリエチレン, High density, melt index 2.2 g/10 min (190 °C/2.16kg)
Sigma-Aldrich
チミジン, ≥99.0% (HPLC)
Sigma-Aldrich
クロム, powder, 99.5%, −100 mesh
Sigma-Aldrich
コバルト, granular, 99.99% trace metals basis
Sigma-Aldrich
チタン, wire, diam. 0.25 mm, 99.7% trace metals basis
Sigma-Aldrich
チタン, sponge, 1-20 mm, 99.5% trace metals basis
Sigma-Aldrich
クロム, chips, 99.995% trace metals basis
チタン, mesh, 100x100mm, nominal aperture 0.19mm, wire diameter 0.23mm, 60x60 wires/inch, open area 20%, twill weave
Sigma-Aldrich
コバルト, Carbon coated magnetic, nanopowder, <50 nm particle size (TEM), ≥99%
Sigma-Aldrich
チタン, foil, thickness 0.025 mm, 99.98% trace metals basis
Sigma-Aldrich
チタン, foil, thickness 2.0 mm, 99.7% trace metals basis
チタン, mesh, 100x100mm, nominal aperture 4.3mm, wire diameter 1.5mm, 4.4x4.4 wires/inch, open area 94%, platinized diamond mesh
Sigma-Aldrich
コバルト, pieces, 99.5% trace metals basis