おすすめの製品
ligand
alkali-stabilized protein A-derived (E. coli)
包装
pack of 1 × 5 mL
メーカー/製品名
Cytiva 11-0034-94
保管条件
(20% Ehtanol)
(20% Ethanol)
パラメーター
<20 mL/min flow rate
42 psi
ベッドサイズ
16 mm × 25 mm
ベッド容積
5 mL
カラム内径
16 mm
Matrix
highly cross-linked agarose
平均部品サイズ
85 μm (d₅₀v is the median particle size of the cumulative volume distribution)
cleaning
2-13.7
動作範囲
3-12
キャパシティ
≥30 mg binding capacity (humanlgG/ml at 2.4 min residence time)
適合性
suitable for bioprocess medium
保管温度
2-8°C
類似した製品をお探しですか? 訪問 製品比較ガイド
関連するカテゴリー
詳細
Determined at 10% breakthrough by frontal analysis at a mobile phase velocity of 500 cm/h in a column with a bed height of 20 cm.
HiTrap® MabSelect™ SuRe™ columns are prepacked with MabSelect™ SuRe, a BioProcess medium for purification of monoclonal antibodies from large sample volumes. The novel alkali-tolerant recombinant Protein A ligand allow cleaning-in-place (CIP).
HiTrap® MabSelect™ columns are prepacked with MabSelect™ a bioprocess medium for capuring of Mabs from large sample volumes.
HiTrap® MabSelect™ columns are prepacked with MabSelect™ a bioprocess medium for capuring of Mabs from large sample volumes.
pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.
特徴および利点
- Withstands rigorous CIP and sanitization procedures with 0.1 to 0.5 M NaOH.
- Novel ligand design gives enhanced protease resistance resulting in lower ligand leakage.
- Oriented coupling of recombinant Protein A to the matrix via an engineered C-terminal cysteine enhances IgG binding capacity.
- Fewer regulatory concerns due to the total absence of mammalian culture in the ligand production and purification.
- Prepacked HiTrap® columns for process development, screening of purification conditions, and small-scale purification of Mabs.
アナリシスノート
この製品の分析証明書は、www.cytiva.com.
その他情報
1)The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
法的情報
Free MabSelect SuRe Ligand
"MabSelect SuRe Ligand Restricted License" and "Cys-rProtein A Ligand Restricted License" are protected by the following patents and equivalent patents and patent applications in other countries: US 6,399,750 and EP 1123389. A free, non-transferable limited license to use this product for internal analytical purposes only accompanies the purchase of the product from a Cytiva company and its licensed distributors. Any other use will require a separate license from a Cytiva company.
"MabSelect SuRe Ligand Restricted License" and "Cys-rProtein A Ligand Restricted License" are protected by the following patents and equivalent patents and patent applications in other countries: US 6,399,750 and EP 1123389. A free, non-transferable limited license to use this product for internal analytical purposes only accompanies the purchase of the product from a Cytiva company and its licensed distributors. Any other use will require a separate license from a Cytiva company.
HiTrap is a registered trademark of Cytiva
MabSelect is a trademark of Cytiva
MabSelect SuRe is a trademark of Cytiva
SuRe is a trademark of Cytiva
シグナルワード
Warning
危険有害性情報
保管分類コード
3 - Flammable liquids
最新バージョンのいずれかを選択してください:
資料
Desalting at laboratory scale is a well-proven, simple, and fast method that will rapidly remove low molecular weight contaminants at the same time as transferring the sample into the desired buffer in a single step.
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)