おすすめの製品
グレード
for HPLC derivatization
品質水準
アッセイ
≥98.5% (HPLC)
品質
LiChropur™
テクニック
HPLC: suitable
蛍光検出
λex 385 nm; λem 524 nm in 0.1 M borate pH 9.5 (after derivatization with glutathione)
保管温度
2-8°C
SMILES記法
N.OS(=O)(=O)c1ccc(F)c2nonc12
InChI
1S/C6H3FN2O4S.H3N/c7-3-1-2-4(14(10,11)12)6-5(3)8-13-9-6;/h1-2H,(H,10,11,12);1H3
InChI Key
JXLHNMVSKXFWAO-UHFFFAOYSA-N
類似した製品をお探しですか? 訪問 製品比較ガイド
保管分類コード
11 - Combustible Solids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
個人用保護具 (PPE)
Eyeshields, Gloves, type N95 (US)
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
46640-5MG-F:
46640-25MG-F:
46640-VAR-F:
46640-BULK-F:
Choose from one of the most recent versions:
Journal of pharmaceutical and biomedical analysis, 10(10-12), 985-988 (1992-10-01)
The present investigation analyses the potentials of capillary chromatography using packed fused silica capillaries filled with 5 microns RP-18 for the fluorescence determination of glutathione in human blood samples. Adaptation of conventional HPLC equipment for miniaturized chromatographic assays proved successful.
Biomedical chromatography : BMC, 23(9), 935-939 (2009-04-09)
A semi-micro column HPLC-fluorescence method for routine determination of thiol derivatives such as homocysteine (Hcy), cysteine (Cys) and cysteamine (CA) is described. The thiol derivatives labeled with ammonium-7-fluorobenzo-2-oxa-1,3-diazole-4-sulfonate (SBD-F) were isocratically separated within 12 min on a semi-micro ODS column
Clinical chemistry, 42(12), 2028-2032 (1996-12-01)
The recognition of homocysteine as a vascular risk factor has led to increased clinical interest in assaying plasma homocysteine concentrations. Our aim was to improve the reliability of a widely used assay based on HPLC of the fluorescent 7-benzo-2-oxa-1, 3-diazole-4-sulfonic
Bioscience, biotechnology, and biochemistry, 75(11), 2119-2124 (2011-11-08)
The analytical method was optimized for L-cysteine (Cys) in rat plasma with co-existing L-cystine (Cyss). We observed that more than 100% Cyss in rat plasma was converted to Cys under typical conditions for the conversion with 7-fluoro-2,1,3-benzoxadiazole-4-sulfonate (SBD-F). Another conversion
Biomedical chromatography : BMC, 10(5), 205-212 (1996-09-01)
A sensitive HPLC-fluorescence method for determining total endogenous plasma homocysteine (Hcy), cysteine (Cys) and cysteinylglycine (Cys-Gly) following derivatization with ammonium 7-fluoro 2,1,3-benzoxadiazole-4-sulphonate (SBD-F) is described. Quantitation utilizes an internal standard, 2-mercaptoethylamine. The derivatization procedure has been optimized for concentration of
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)