The human ether-a-go-go related gene (hERG) is a potassium ion channel which is essential for normal cardiac repolarization. In drug screening models, the hERG K+ channel has been indicated to inhibit a wide variety of compounds, and its blockage can lead to cardiac QT interval prolongation and life threatening arrhythmias (Murphy et al. 2006). Cardiac safety relating to IKr K+ channels has become a major concern of regulatory agencies, as hERG channel inhibition has been identified as the firmest link to QT prolongation (Chiu et al. 2004). Millipore′s hERG membrane preparations are crude membrane preparations made from HEK293 stable recombinant cell lines (Millipore cat. # CYL3039), which are ideal HTS tools for screening antagonists against the hERG channel. The membrane preparations exhibit a Kd of 5.2 nM for [3H]-Astemizole. With 10 μg/well hERG Membrane Prep and 3.0 nM [3H]-Astemizole, a greater than 4-fold signal-to-background ratio was obtained.
細胞株の説明
GPCR Cell Lines
アプリケーション
Radioligand binding assay
生物化学的/生理学的作用
Protein Target: hERG
Target Sub-Family: Potassium
品質
Table 1. Signal: background and specific binding values obtained in a competition binding assay for the hERG membrane prep.
SPECIFICATIONS: 1 unit = 10 μg membrane preparation with [3H]-astemizole
Bmax with [3H]-astemizole: 6.7 pmol/mg
Kd for [3H]-astemizole: 5.2 nM
Table 2. Rank order comparison of various small molecule hERG inhibitors using [3H]-astemizole binding assay and E-Phys assays:
*Data obtained from Chiu et al., 2004
10 µg/well | |
---|---|
Signal:Background | 4.6 |
Specific Binding (cpm) | 435 |
SPECIFICATIONS: 1 unit = 10 μg membrane preparation with [3H]-astemizole
Bmax with [3H]-astemizole: 6.7 pmol/mg
Kd for [3H]-astemizole: 5.2 nM
Table 2. Rank order comparison of various small molecule hERG inhibitors using [3H]-astemizole binding assay and E-Phys assays:
Binding Ki (nM) with hERG membrane preps | Electrophysiology IC50 (nM) with hERG cell lines | ||||
Millipore CYL4039M | Literature value* | Millipore CYL4039 by IonWorks PPC | Millipore CYL4039 by PatchExpress | Literature value by Patch Clamp | |
Astemizole | 3.4 ± 0.7 | 3.3 ± 0.7 | 4.6 ± 0.003 | ND | 0.5 |
Dofetilide | 5.8 ± 2.4 | 28 ± 6 | ND | ND | 15.3 ± 2.5 |
E-4031 | 6.1 ± 0.8 | 58 ± 5 | 115 ± 0.02 | 144 ± 44 | 14 |
Pimozide | 18.8 ± 2.3 | 14 ± 4 | ND | ND | 18 |
Cisapride | 104.9 ± 30.9 | 123 ± 25 | 75.6 ± 0.02 | 5 ± 1 | 44.5 ± 10.6 |
Haloperidol | 241.4 ± 21.4 | 234 ± 20 | ND | ND | 63 |
Risperidone | >4000 | 4302 ± 319 | ND | ND | 167 |
Verapimil | >4000 | 3902 ± 529 | 1332 ± 120 | 3100 ± 400 | 830 |
*Data obtained from Chiu et al., 2004
規格
Inucbation Conditions
RECOMMENDED ASSAY CONDITIONS: Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, an FB 96-well harvest plate (Millipore cat. # MAHF B1H) is coated with 0.33% polyethyleneimine for 30 min, then washed with 25 mM Tris, pH 7.4, 130 mM NaCl, 5 mM KCl, 0.8 mM CaCl2, 0.1% BSA. Binding reaction is transferred to the filter plate, and washed 6 times (250μL per well per wash) with Wash Buffer. The plate is dried and counted.
Binding buffer: 10 mM Hepes, pH 7.4, 130 mM NaCl, 5 mM KCl, 0.8 mM MgCl2, 1 mM NaEGTA, 10 mM glucose, 0.1% BSA, filtered and stored at 4°C
Radioligand: [3H]-Astemizole (Perkin Elmer # NET-1140)
Wash Buffer: 25 mM Tris, pH 7.4, 130 mM NaCl, 5 mM KCl, 0.8 mM MgCl2, 0.05 mM CaCl2, 0.1% BSA, filtered and stored at 4°C
One package contains enough membranes for at least 200 assays (units), where a unit is the amount of membrane that will yield greater than 4-fold signal: background with 3H-labeled Astemizole.
RECOMMENDED ASSAY CONDITIONS: Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, an FB 96-well harvest plate (Millipore cat. # MAHF B1H) is coated with 0.33% polyethyleneimine for 30 min, then washed with 25 mM Tris, pH 7.4, 130 mM NaCl, 5 mM KCl, 0.8 mM CaCl2, 0.1% BSA. Binding reaction is transferred to the filter plate, and washed 6 times (250μL per well per wash) with Wash Buffer. The plate is dried and counted.
Binding buffer: 10 mM Hepes, pH 7.4, 130 mM NaCl, 5 mM KCl, 0.8 mM MgCl2, 1 mM NaEGTA, 10 mM glucose, 0.1% BSA, filtered and stored at 4°C
Radioligand: [3H]-Astemizole (Perkin Elmer # NET-1140)
Wash Buffer: 25 mM Tris, pH 7.4, 130 mM NaCl, 5 mM KCl, 0.8 mM MgCl2, 0.05 mM CaCl2, 0.1% BSA, filtered and stored at 4°C
One package contains enough membranes for at least 200 assays (units), where a unit is the amount of membrane that will yield greater than 4-fold signal: background with 3H-labeled Astemizole.
物理的形状
Liquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA with no preservatives.
Packaging method: Membrane protein was adjusted to the indicated concentration in packaging buffer, rapidly frozen, and stored at -80°C.
Packaging method: Membrane protein was adjusted to the indicated concentration in packaging buffer, rapidly frozen, and stored at -80°C.
保管および安定性
Maintain frozen at –70°C up to expiration date indicated on the label. Do not freeze and thaw.
法的情報
Precision B+ is a registered trademark of Precision Scientific
免責事項
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
保管分類コード
10 - Combustible liquids
WGK
WGK 2
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
CYL4039:
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)