Skip to Content
Merck
  • A new approach for automated liquid-liquid extraction in a sequential injection manifold.

A new approach for automated liquid-liquid extraction in a sequential injection manifold.

Analytical and bioanalytical chemistry (2014-11-06)
Irene Delgado-Blanca, Eulogio J Llorent-Martínez, Antonio Ruiz-Medina, Pilar Ortega-Barrales
ABSTRACT

A new approach for the implementation of liquid-liquid extraction in a sequential injection manifold is presented. The manifold consists of two syringe pumps and one multi-position valve. The use of a 30 % MeOH/H2O (v/v) solution as the carrier, with isobutanol as the extractant, made it possible to avoid the problems associated with the different affinities of the organic and aqueous phases for Teflon tubing, and the formation of bubbles. The suitability of the proposed method was demonstrated by the determination of thiamine in pharmaceutical preparations and dietary supplements. Detection and quantification limits were estimated as 9 and 30 μg L(-1), respectively. The repeatability was lower than 3 % and the intermediate precision (3 d) was lower than 7 %. The sample throughput was 14 samples per h. The results were in agreement with a high-performance liquid chromatography-electrospray/mass spectrometry reference method.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Chloroform, suitable for HPLC
Supelco
Thiamine hydrochloride, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Chloroform, JIS special grade, ≥99.0%
Sigma-Aldrich
Methanol, SAJ special grade
Sigma-Aldrich
Chloroform, JIS 300, ≥99.0%, for residue analysis
Sigma-Aldrich
Chloroform, SAJ super special grade, ≥99.0%
Sigma-Aldrich
2-Methyl-1-propanol, JIS special grade, ≥99.0%
Sigma-Aldrich
2-Methyl-1-propanol, SAJ first grade, ≥99.0%
Sigma-Aldrich
Chloroform, SAJ first grade, ≥99.0%, contains 0.4-0.8% ethanol
Supelco
Heptafluorobutyric acid solution, 0.5 M in H2O, LiChropur, suitable for ion pair chromatography
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
USP
Thiamine hydrochloride, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
2-Methyl-1-propanol, anhydrous, 99.5%
Supelco
Chloroform, suitable for HPLC, ≥99.8%, contains 0.5-1.0% ethanol as stabilizer
Supelco
Thiamine Hydrochloride (B1), analytical standard
Sigma-Aldrich
2-Methyl-1-propanol, BioUltra, for molecular biology, ≥99.5% (GC)
Supelco
Chloroform, analytical standard
Sigma-Aldrich
Thiamine hydrochloride, tested according to Ph. Eur.
Supelco
2-Methyl-1-propanol, analytical standard
Supelco
Methanol, analytical standard
Sigma-Aldrich
Chloroform, ACS reagent, ≥99.8%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
Chloroform, ACS reagent, ≥99.8%, contains amylenes as stabilizer
Sigma-Aldrich
Chloroform, anhydrous, contains amylenes as stabilizer, ≥99%
Sigma-Aldrich
Chloroform, anhydrous, ≥99%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
Chloroform, ≥99%, PCR Reagent, contains amylenes as stabilizer
Sigma-Aldrich
Thiamine hydrochloride, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture
Sigma-Aldrich
Thiamine hydrochloride, meets USP testing specifications
Sigma-Aldrich
Thiamine hydrochloride, reagent grade, ≥99% (HPLC)
Supelco
Chloroform, Pharmaceutical Secondary Standard; Certified Reference Material