Passa al contenuto
Merck
Tutte le immagini(1)

Key Documents

G005805

GC Analysis of Pesticides in Avocado on SLB®-5ms (20 m x 0.18 mm I.D., 0.36 μm) after QuEChERS Cleanup using Supel QuE Z-Sep+, Fast GC Analysis

application for SPE, suitable for GC

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

tecniche

gas chromatography (GC): suitable
solid phase extraction (SPE): suitable

Parametri analitici

sample preparation: Dispersive (QuEChERS)
sample/matrix: Avocado spiked with pesticides at 20 ng/g
extraction tube: Supel QuE Acetate extraction tube (55234-U)
extraction process: add 25 mL of acetonitrile; shake for 1 minute; add contents of Supel QuE acetate extraction tube; shake immediately for 1 minute; centrifuge at 3200 rpm for 5 minutes
clean-up tube: Supel Que Z-Sep+ cleanup tube (55296-U)
clean-up process: transfer 3 mL of the acetonitrile layer into a Supel Que Z-Sep+ cleanup tube; shake for 1 minute; centrifuge at 3400 rpm for 3 minutes; draw off supernatant for LVI-GCMS analysis
column: SLB-5ms, 20 m x 0.18 mm I.D., 0.36 μm (28576-U)
oven: 70 °C (2 min), 15 °C/min to 325 °C (6 min)
inj. temp.: 60 °C (0.28 min), 600 °C/min to 325 °C (5 min)
detector: MSD
MSD interface: 330 °C
carrier gas: helium, 1 mL/min, constant
injection: PTV solvent vent; 10 μL, injection dispense speed 15000 μL/min
liner: 4 mm I.D. FocusLiner with taper
sample: pesticides spiked at 20 ng/g

Compatibilità

application for SPE

applicazioni

agriculture
food and beverages

Risultati analitici

About this analysis: This application demonstrates the use of dispersive SPE for the extraction of pesticides from Avocado. Cleanup is achieved using Z-Sep + for fat removal. FInal analysis of the extracts was done by LVI-GC/MS SIM on an SLB-5ms column.

Note legali

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany
Supel is a trademark of Sigma-Aldrich Co. LLC

Analita

Descrizione

    Trifluralin
    α-1,2,3,4,5,6-Hexachlorocyclohexane
    Hexachlorobenzene
    Dimethoate
    Simazine
    Pentachloronitrobenzene
    Lindane
    Heptachlor
    Malathion
    Metolachlor
    4,4′-DDT
    Methoxychlor
    Coumaphos
    Deltamethrin
    Vedi tutto (14)

Colonnina o piastra per SPE

N° Catalogo
Descrizione
Determinazione del prezzo

Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Ci dispiace, ma al momento non ci sono COA disponibili online per questo prodotto.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.