Passa al contenuto
Merck
Tutte le immagini(1)

Documenti

06855

Sigma-Aldrich

Poli(etilenglicole)

Sinonimo/i:

PEG

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula condensata:
H(OCH2CH2)nOH
Numero CAS:
Numero MDL:
Codice UNSPSC:
12161900
NACRES:
NA.25

Forma fisica

liquid

PM

average Mw 380-420 g/mol (from OH-value (56100*2/OHZ))

tecniche

electrophoresis: suitable

Impurezze

reducing substances, complies
≤0.1% sulfated ash
≤0.25% ethylene glycol and diethylene glycol (sum)
≤0.5 g acetic acid (per 100 g)
≤1 ppm ethylene oxide
≤1 ppm lead (verified on random samples only)
≤1.0% water
≤10 ppm dioxan
≤15 ppm formaldehyde
≤5 ppm heavy metals (verfied on random samples only)
≤620 ppm ethylene glycol

pH

4.5-7.0 (50 g/L)

Viscosità

105-130 mPa.s(20 °C) (6.8-8.0 CS (98.9°C)

Indice di ossidrile

267‑295 mg KOH/g

Solubilità

H2O: 10%, clear, colorless

Compatibilità

complies for acidity or alkalinity

Stringa SMILE

C(CO)O

InChI

1S/C2H6O2/c3-1-2-4/h3-4H,1-2H2
LYCAIKOWRPUZTN-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Applicazioni

Kollisolv polyethylene glycols are used as thickening agents and gel binders in the pharmaceutical industry.
This research grade product is intended for use in R&D and development only.

Altre note

The PEG E grades of Kollisolv are polyethylene glycols (macrogols) of different molecular weights.

Note legali

Kollisolv is a registered trademark of BASF

Codice della classe di stoccaggio

10 - Combustible liquids

Classe di pericolosità dell'acqua (WGK)

WGK 1

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

M Patel Geeta et al.
Current drug delivery, 6(2), 159-165 (2009-05-20)
Carbamazepine indicated for the control of epilepsy, undergoes extensive hepatic first-pass metabolism after oral administration. A vaginal dosage form of carbamazepine is not commercially available. Conventional suppository having poor retention in the vaginal tract, as they are removed in a
D D Smyth et al.
Cardiovascular drugs and therapy, 4(1), 297-300 (1990-02-01)
Previous studies have demonstrated that Separan AP-30, a drag-reducing polymer, significantly decreased the formation of atherosclerotic plaques in rabbits fed a high-cholesterol diet. Furthermore, Separan AP-273, a polymer similar to but longer than Separan AP-30, markedly increased cardiac output in
I L Konorova et al.
Patologicheskaia fiziologiia i eksperimental'naia terapiia, (4)(4), 7-9 (1991-07-01)
The search for antiaggregatory compounds is undertaken, as a rule, under in vitro conditions which do not reflect the dynamics of the real process. The present work deals with study of the peculiarities of the development of the collagen induced
P I Polimeni et al.
Journal of cardiovascular pharmacology, 14(3), 374-380 (1989-09-01)
The acute hemodynamic effects of an intravenously (i.v.) injected poly(ethylene oxide), Polyox WSR N-60K (dose 50 mg/kg), were studied in the open-chest rat anesthetized with sodium pentobarbital. The injectate is one of four drag-reducing polymers known to augment in vitro

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.