Passa al contenuto
Merck
Tutte le immagini(4)

Documenti

71016BC

Millipore

GDS MPX Top 6 STEC

BioControl, Molecular based PCR test for the detection of the "Top Six" non-O157 Shiga Toxigenic E. coli (STEC) in food

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
41106302
NACRES:
NB.61

Livello qualitativo

Durata

6‑12 mo.

Produttore/marchio commerciale

BioControl Systems 71016-100

Temperatura di conservazione

2-8°C

Descrizione generale

GDS MPX Top 6 STEC is an automated nucleic acid amplification system for the detection of the “Top Six” non-O157 Shiga Toxigenic E. coli (STEC) in raw ground beef, raw beef trim, raw spinach, and raw mixed greens (baby lettuce and other young leafy green vegetables). The "Top Six" non-O157 STEC are defined as E. coli belonging to serogroups O103, O111, O121, O145, O26 or O45 that possess both the eae gene and at least one of the Shiga Toxin Genes stx1 or stx2. GDS MPX Top 6 STEC utilizes a proprietary IMS-based sample preparation procedure to isolate organisms belonging to 6 specific Top STEC O-serogroups (O103, O111, O121, O145, O26 and O45) prior to genetic analysis for the associated pathogenicity genes.

Caratteristiche e vantaggi

  • Following sample preparation with IMS against the Top 6 O groups, samples are analyzed with a single multiplex assay for the presence of (eae), stx1, and stx2
  • Single-step 10-18 h enrichment in mEHEC®, enrichment media common to all BioControl methods for E.coli O157:H7, Shiga Toxin genes, and Top STEC

Componenti

  • MPX Top STEC Amplification Tubes
  • Top 6 STEC Concentration Reagent
  • Resuspension Buffer Tq
  • Top STEC Wash Solution

Compatibilità

BioControl GDS

Metodo analitico

PCR, Immunomagnetic Separation (IMS)

Note legali

mEHEC is a registered trademark of Merck KGaA, Darmstadt, Germany

Pittogrammi

Corrosion

Avvertenze

Warning

Indicazioni di pericolo

Consigli di prudenza

Classi di pericolo

Met. Corr. 1

Codice della classe di stoccaggio

8A - Combustible corrosive hazardous materials

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Choose from one of the most recent versions:

Certificati d'analisi (COA)

Lot/Batch Number

Sorry, we don't have COAs for this product available online at this time.

If you need assistance, please contact Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.