Passa al contenuto
Merck

Vai a

KVVLA04FF3

Durapore® 0.1 µm, Opticap® XL Capsule

Opticap® XL 4, inlet connection diam. 3/4 in., cartridge nominal length 4 in. (10 cm)

Sinonimo/i:

Opticap XL4 Durapore 0.1 μm 3/4 in. TC/TC, Durapore® 0.1 µm, Opticap® XL Capsule

Autenticati per visualizzare i prezzi organizzativi e contrattuali.

Scegli un formato

Cambia visualizzazione
Voi/SKUDisponibilitàPrezzo
3 ea

Informazioni su questo articolo

UNSPSC Code:
23151806

Non è possibile acquistare questo articolo come utente ospite. Per ulteriori informazioni ti preghiamo di contattarci +39 02 38 59 40 13o

.

Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti


Nome del prodotto

Capsule Opticap® XL, membrana Durapore® da 0,1 µm,, Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF)Inlet: 3/4 in. Sanitary FlangeOutlet: 3/4 in. Sanitary FlangeMax Operating Pressure: 80 psi @ 25 °C

Quality Segment

material

PVDF , polypropylene , polypropylene housing, polypropylene support, polypropylene vent cap, silicone seal

reg. compliance

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterility

non-sterile

sterilization compatibility

autoclavable compatible

product line

Opticap® XL 4

feature

hydrophilic

manufacturer/tradename

Opticap®

parameter

≤7.5 mL/min air diffusion at 3.9 bar (56 psig) and 23 °C (in water), 1.0 bar max. differential pressure (15 psid) at 80 °C (Forward), 1.0 bar max. inlet pressure (15 psi) at 80 °C, 2.8 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent), 5.5 bar max. differential pressure (80 psid) at 25 °C (Forward), 5.5 bar max. inlet pressure (80 psi) at 23 °C, 80 psig max. inlet pressure

technique(s)

sterile filtration: suitable

L

18.8 cm (7.4 in.)

cartridge nominal length

4 in. (10 cm)

diam.

14.5 cm (5.7 in.)

filtration area

0.19 m2

inlet connection diam.

3/4 in.

inlet to outlet W

18.8 cm (7.4 in.)

outlet connection diam.

3/4 in.

impurities

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction), <0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

gravimetric extractables

≤10 mg/capsule

matrix

Durapore®

pore size

0.1 μm

input

sample type liquid

bubble point

≥4830 mbar (70 psig), air with water at 23 °C

fitting

1/4 in. drain/vent hose barb (with double O-ring Seal), (19 mm (3/4 in.) Sanitary Flange Inlet and Outlet)

General description

Device Configuration: Capsule

Packaging

Double Easy-Open bag

Preparation Note

Sterilization Method
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: after 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥500 mL

Other Notes

Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 1

Questo articolo
KVVLA04TT3KVVLA04FH3KVVLA04TH3
description

Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF)Inlet: 3/4 in. Sanitary FlangeOutlet: 3/4 in. Sanitary FlangeMax Operating Pressure: 80 psi @ 25 °C

description

Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF)Inlet: 1-1/2 in. Sanitary FlangeOutlet: 1-1/2 in. Sanitary FlangeMax Operating Pressure: 80 psi @ 25 °C

description

Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF)Inlet: 3/4 in. Sanitary FlangeOutlet: 9/16 in. Hose BarbMax Operating Pressure 80 psi @ 25 °C

description

Chemistry: Hydrophilic Polyvinylidene Fluoride (PVDF)Inlet: 1-1/2 in. Sanitary FlangeOutlet: 9/16 in. Hose BarbMax Operating Pressure: 80 psi @ 25 °C

pore size

0.1 μm

pore size

0.1 μm

pore size

0.1 μm

pore size

0.1 μm

filtration area

0.19 m2

filtration area

0.19 m2

filtration area

0.19 m2

filtration area

0.19 m2

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

product line

Opticap® XL 4

product line

Opticap® XL 4

product line

Opticap® XL 4

product line

Opticap® XL 4

matrix

Durapore®

matrix

Durapore®

matrix

Durapore®

matrix

Durapore®

manufacturer/tradename

Opticap®

manufacturer/tradename

Opticap®

manufacturer/tradename

Opticap®

manufacturer/tradename

Opticap®


Still not finding the right product?




Mantenere la conformità alle GMP utilizzando il programma Emprove®.

Accelerate la qualificazione, mantenete la conformità e risparmiate tempo con Emprove® Dossiers.

Scarica Dossiers

Nota: verrete portati su EmproveSuite.com. Il vostro nome utente e la vostra password sono separati da SigmaAldrich.com e possono essere diversi.

Registrati gratuitamente e accedi a Emprove® Dossiers in pochi minuti. Aggiornate il vostro piano di abbonamento per sbloccare contenuti avanzati e personalizzati nella Emprove® Suite.

Non trovate quello che state cercando? Visitate la pagina di aiuto del programma Emprove®..

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Non riesci a trovare il codice del tuo prodotto o il numero di lotto/ batch?

I numeri di catalogo dei prodotti nel sito internet sono associati al taglio o alla quantità delle confezioni (es: T1503-25G). Accertati Nel campo N° Catalogo digita SOLO il N° di catalogo del prodotto (Esempio: T1503).

Esempio:

T1503
Numero di prodotto
-
25G
Confezione/Quantità

Altri esempi:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

Inseriscilo come 1.000309185)

Problemi? Sentitevi liberi di contattare Servizio Tecnico per chiedere aiuto



Domande

Recensioni

Nessuna valutazione

Filtri attivi